CSAT3B
CSAT3B
Limited availabilityConfigurableGSA3-D Sonic Anemometer with Integrated Electronics
Pricing
Configuration
Sign in for option pricing- Sonic Carrying CaseCSAT3B-SC
- No Carrying CaseCSAT3B-NC
Select a configuration to add to your quote
- Model:
- CSAT3B
- Item Number:
- CSAT3B
- Warranty:
- 1 year
- Lead time:
- 14 days
Overview
Campbell Scientific’s CSAT3B 3-D Sonic Anemometer is an update and replacement to the original CSAT3, and remains the 3-D sonic anemometer of choice for eddy-covariance measurements. It has an aerodynamic design, a 10 cm vertical measurement path, operates in a pulsed acoustic mode, and withstands exposure to harsh weather conditions. Three orthogonal wind components (ux, uy, uz) and the sonic temperature (Ts) are measured and output at a maximum rate of 100 Hz.
The most conspicuous innovation of the new design is the elimination of the electronics box. Instead, the electronics are packaged inside the mounting block of the CSAT3B head. This design feature makes installation easier and offers greater flexibility in instrument placement.
Measurements can be triggered from three sources:
- Data logger SDM command
- Data logger CPI command
- CSAT3B internal clock
The SDM and CPI protocols both support mechanisms for synchronizing multiple CSAT3Bs.
Key Advantages
Designed for flux and other turbulence research projects
Benefits
- New conformal coating helps protect sonic transducers in corrosive environments
- Integrated electronics that provide easy mounting of a single piece of hardware
- Integrated inclinometer
- High-precision measurements ideal for turbulence and eddy-covariance studies
- An improved design with a thin, aerodynamic support strut close to the ends of the sensor arms, creating greater rigidity and improved accuracy of sonic temperature
- Data logger sampling supported for any frequency between 1 and 100 Hz
- New CPI communications for more robust, higher bandwidth measurements
- Multiple communication options including SDM, CPI, USB, and RS-485
- Internal temperature and humidity measurements with easily replaced desiccant
- Version 5 algorithm for calculating data outputs; combines the signal sensitivity of version 3 with the rain performance of version 4
- Includes options to filter high frequencies for applications requiring analysis of non-aliased spectra
Specifications
- Sensor
- 3-dimensional sonic anemometer
- Measurement Description
- Highest-quality wind speed and direction
- Operating Temperature Range
- -40 to +50°C
(equivalent to 305 to 368 m s-1 in speed of sound)
- Outputs
- ux, uy, uz, Ts
(ux, uy, uz are wind components referenced to the anemometer axes; Ts is sonic temperature in degrees Celsius.)
- Signal Type/Output
- SDM, CPI, USB, RS-485
- Speed of Sound
- Determined from three acoustic paths.
(Corrected for crosswind effects.)
- Wind Direction Range
- 2.5 to 357.5° in CSAT3B coordinate system
(0 to 360° customized)
- Range
- ± 65 m s–1
(full-scale wind)
- Filter Bandwidths
- 5, 10, or 25 Hz
- Measurement Path Length
- 10.0 cm (3.9 in.) vertical; 5.8 cm (2.3 in.) horizontal
- Transducer Angle from Horizontal
- 60 degrees
- Ingress Protection
- IP67
- Transducer Diameter
- 0.64 cm
(0.25 in.)
- Transducer Mounting Arm Diameter
- 0.84 cm
(0.33 in.)
- Support Arm Diameter
- 1.59 cm
(0.63 in.)
- Anemometer Head Weight
- 1.45 kg
(3.2 lb)
- Anemometer Dimensions
- 60.64 x 12.2 x 43.0 cm
(23.87 x 4.8 x 16.9 in.)
Wind Accuracy
- -NOTE-
- Accuracy specifications assume the following:
-40° to +50°C operating rangeWind speeds < 30 m s-1Wind angles between ±170°
- Maximum Offset Error
- < ±8.0 cm s-1 (ux, uy), < ±4.0 cm s-1 (uz)
- Maximum Gain Error
- < ±2% of reading
(wind vector within ±5° of horizontal)
- Maximum Gain Error
- < ±3% of reading
(wind vector within ±10° of horizontal)
- Maximum Gain Error
- < ±6% of reading
(wind vector within ±20° of horizontal)
Measurement Resolution
- ux, uy
- 1 mm s-1 rms
- uz
- 0.5 mm s-1 rms
- Ts
- 0.002°C RMS
(at 25°C)
- Wind Direction
- < 0.058°
(ux = uy ≤ 1 m s-1)
Measurement Rates
- Data Logger Triggered
- 1 to 100 Hz
- Unprompted Output (to PC)
- 10, 20, 50, or 100 Hz
- Internal Self-Trigger Rate
- 100 Hz
Measurement Delay
- Data Logger Triggered (no filter)
- 1 trigger period
(1 scan interval)
- Unprompted Output (no filter)
- 10 ms
- Filtered Output (data-logger-prompted or unprompted to PC)
- 795 ms
(with 5 Hz bandwidth filter)
- Filtered Output (data-logger-prompted or unprompted to PC)
- 395 ms
(with 10 Hz bandwidth filter)
- Filtered Output (data-logger-prompted or unprompted to PC)
- 155 ms
(with 25 Hz bandwidth filter)
Internal Monitor Measurements
- Update Rate
- 2 Hz
- Inclinometer Accuracy
- ±1°
- Relative Humidity Accuracy
- ±3%
(over 10 to 90% range)
- Relative Humidity Accuracy
- ±7%
(over 0 to 10% range)
- Relative Humidity Accuracy
- ±7%
(over 90 to 100 % range)
- Board Temperature Accuracy
- ±2°C
SDM
- -NOTE-
- Used for data-logger-based data acquisition.
- Bit Period
- 10 µs to 1 ms
- Cable Length
- 7.6 m (25 ft) max
(@ 10 µs bit period)
- Cable Length
- 76 m (250 ft) max
(@ 1 ms bit period)
- Address Range
- 1 to 14
- Bus Clocks per Sample
- ~200
CPI
- -NOTE-
- Used for data-logger-based data acquisition.
- Baud Rate
- 50 kbps to 1 Mbps
- Cable Length
- 15 m (50 ft) max
(@ 1 Mbps)
- Cable Length
- 122 m (400 ft) max
(@ 250 kbps)
- Cable Length
- 853 m (2800 ft) max
(@ 50 kbps)
- Address Range
- 1 to 120
- Bus Clocks per Sample
- ~300
RS-485
- -NOTE-
- Used for configuration or PC-based data acquisition.
- Baud Rate
- 9.6 kbps to 115.2 kbps
- Cable Length
- 305 m (1000 ft) max
(@ 115.2 kbps)
- Cable Length
- 610 m (2000 ft) max
(@ 9.6 kbps)
- Bus Clocks per Sample
- ~500
(ASCII formatted)
USB
- -NOTE-
- Used for configuration or PC-based data acquisition.
- Connection Speed
- USB 2.0 full speed 12 Mbps
- Cable Length
- 5 m (16.4 ft) maximum
Power Requirements
- Voltage Supply
- 9.5 to 32 Vdc
- Current at 10 Hz Measurement Rate
- 110 mA
(@ 12 Vdc)
- Current at 10 Hz Measurement Rate
- 65 mA
(@ 24 Vdc)
- Current at 100 Hz Measurement Rate
- 145 mA
(@ 12 Vdc)
- Current at 100 Hz Measurement Rate
- 80 mA
(@ 24 Vdc)
Accessories
(17)CSAT3BCBL2
Power-Only Cable for CSAT3B
OrderableCSAT3BCBL3
CPI/RS-485 Cable for CSAT3B
OrderableCSAT3BCBL1
Power/SDM Cable for CSAT3B
Orderable4335
10 AWG Green Copper Stranded Wire
Orderable30293
CSAT3B Power/SDM Splitter
End of life30294
CSAT3B CPI/RS-485 Splitter
Retired32473
Power Cable Compensation Plug for the CSAT3B
Orderable10080
Thermocouple Cover for CSAT3, CSAT3B, or IRGASON
Orderable31423
Fine-Wire Thermocouple Cover Backplate
OrderableFW05
Type E Fine-Wire Thermocouple with 0.0005 in. Diameter
OrderableFW/ENC
Fine-Wire Thermocouple Carrying Case (hold four thermocouples)
OrderableFWC
Connector Cable for Fine-Wire Thermocouples
OrderableHUB-SDM8
8-Channel Hub for SDM Peripherals and Power Connections
OrderableCABLE5CBL
5-Conductor 22 AWG Cable with Drain
OrderableHUB-CPI
8-Channel RJ45 Hub for CPI Peripherals
Orderable28899
CAT6 Ethernet Unshielded Cable with RJ45 Connectors, 2 ft
Orderable38476
16 GB microSD Flash aMLC Memory Card
Orderable
Related Resources
Case Studies
Documents
- Manual
CSAT3B Packing Information
January 2019
View Document - Document
CSAT3B Cabling Options Diagram
September 2014
View Document - Brochure
CSAT3B 3-D Sonic Anemometer with Integrated Electronics
April 2026
View Document - Technical Paper
Recovery of the three-dimensional wind and sonic temperature data from a physically deformed sonic anemometer
October 2018
View Document - View all documents