The TGA200A Trace Gas Analyzer measures trace gas concentrations in an air sample using tunable-diode laser absorption spectroscopy (TDLAS). This technique provides high sensitivity, speed, and selectivity. Its simple design allows it to measure one of many gases by choosing an appropriate laser source. The TGA200A features a 1.5 m single-pass optical measurement system that uses a thermoelectrically cooled laser.
The TGA200A is housed in a rugged environmental enclosure designed for use in demanding climates ranging from high-latitude boreal forests, permafrost, and tundra to agriculturally intensive mid-latitude regions and equatorial rainforests. Common applications include slow-gradient or high-speed eddy-covariance measurements of nitrous oxide fluxes or carbon fluxes in the form of methane, or isotopologs of carbon dioxide in all global ecosystems.
Campbell Scientific has been manufacturing TGAs since 1993, and the TGA200A is the result of over 20 years of research and development. Even though previous generations of the TGA (TGA100, TGA100A, and TGA200) have the same core technology, the TGA200A builds upon this succession with further improvements. For more information about the TGA200A, contact Campbell Scientific, Inc.
Key Advantages
Measures CO2 isotopes,
N2O, or CH4
Benefits
- Small sample cell volume that provides superior frequency response
- Thermoelectrically cooled laser; no cryogenic cooling required
- Laser upgrades available to existing TGA customers; contact Campbell Scientific for more information
- Choice of laser sources to measure CO<sub>2</sub> isotopes, N<sub>2</sub>O, or CH<sub>4</sub>
- Optically simple measurement system that does not require cleaning of the optical cell in the field
- 500 Hz measurement rate that supports excellent synchronization
- Rugged environmental enclosure that allows the TGA200A to be placed outside on the ground
- Simple Windows user interface for setup, configuration, and real-time monitoring
- Complete greenhouse gas measurement flux solution provided by combining one or more TGA200As with Campbell Scientific’s sonic anemometers, data loggers, gas analyzers, closed-path gas analyzers, or eddy-covariance system
- Advanced sampling systems also available for low-flow applications such as profile, gradient, or user-supplied chamber measurements
Specifications
- Measurement Rate
- 500 Hz
- Sample Cell Volume
- 200 mL
- Dimensions
- 211 x 47 x 55 cm
(83 x 18.5 x 21.5 in.)
- Weight
- 5.4 kg
(12.0 lb) for power module with cable
- Weight
- 62.8 kg
(138.5 lb) for TGA200A
Typical Measurement Noise
- -NOTE-
- Preliminary Results
Allan deviation with 100 ms averaging time. - Nitrous Oxide (N2O) - Laser pn 30478
- 1.5 nmol mol-1
- Methane (CH4) - Laser pn 30477
- 7.0 nmol mol-1
- Nitrous Oxide (N2O) - Laser pn 31121
- 1.8 nmol mol-1
- Carbon Dioxide (CO2) - Laser pn 31121
- 0.3 μmol mol-1
(based on the 13C16O16O isotopolog)
- Carbon Dioxide (CO2) - Laser pn 31119
- 0.15 μmol mol-1
- δ13C - Laser pn 31119
- 0.5 ‰
- Carbon Dioxide (CO2) - Laser pn 30877
- 0.5 μmol mol-1
- δ13C - Laser pn 30877
- 2.0 ‰
- δ18O - Laser pn 30877
- 2.0 ‰
Power Requirements
- Analyzer (TE-cooled laser)
- 90 to 264 Vac, 47 to 63 Hz, 34 W (max) 22 W (typical)
- Heater
- 90 to 264 Vac, 47 to 63 Hz, 150 W (max) 50 W (typical)
Accessories
(13)15837
TGA Reference Gas Connection, 20 ft Tubing
Orderable16599
TGA Insulated Enclosure Cover
Orderable17882
TGA Air Sample Intake
Orderable18072
TGA Heated Intake Filter
Orderable20553
Replacement High-Flow Filter Holder
RetiredXDD1
Sample Pump with Fittings, 50 ft of Tubing
OrderableDOAV502
Sample Pump Modified with 100 ft Tubing
RetiredDAAV505
Gast Sample Pump, 107.6 lpm Free Flow, Modified
RetiredPD1T
Single Tube Sample Dryer, 6 ft
OrderablePD1T-1.5
Single Tube Sample Dryer, 1.5 ft
OrderablePD200T
High-Flow Sample Dryer, 4 ft
OrderablePD625
TGA Low Flow Sample Dryer
Retired19541
TGA Rotameter (4 to 40 lpm) with 3/8 in. Tube Fittings
Orderable
Related Resources
Documents
- Document
Performance Evaluation of a New, Tunable-Diode Laser Trace Gas Analyzer for Isotope Ratios of Carbon Dioxide Poster
View Document - Document
Frequency Response of a New Closed-Path, Trace Gas Analyzer for Eddy-Covariance Flux Measurements Poster
View Document - Document
A Novel Low-Power, High-Performance, Zero-Maintenance Closed-Path Trace Gas Eddy-Covariance System with No Water Vapor Dilution or Spectroscopic Corrections Poster
View Document - Document
A Low-Power Configuration for a Tunable Diode Laser Trace Gas Analyzer to Measure N2O and CO2 Fluxes Using Flux Gradient Method
View Document - View all documents