CR295X
CR295X
RetiredDatalogger for GOES Satellite Communication
Pricing
- Model:
- CR295X
- Item Number:
- 21946
- Warranty:
- 3 years
Overview
The CR295X is a small, low-cost data logger that reads input from one or two sensors, then transmits the data using the GOES satellite transmitter. Multiple CR295Xs can be configured as a network, or units can be deployed individually. CRBasic, its full programming language, supports simple or complex programming and many onboard data reduction processes. It supports stand-alone operation in harsh, remote environments.
Key Advantages
Good for SDI-12 measurements
Technical Description
The CR295X includes an additional RS-232 serial port that allows communications with the TX320, TX312, or SAT HDR GOES satellite transmitter. It has several input channels for measuring a variety of sensors. Gas discharge tubes provide rugged electrostatic discharge protection for the inputs.
The CR295X does not make differential measurements and is not compatible with SDM devices, multiplexers, or thermocouples. (Refer to the Compatibility information on the web page for compatible sensors, peripherals, and software.) Recalibration services are not offered for the CR295X dataloggers.
Benefits
- Small, low-cost data logger designed for use with GOES satellite transmitters
- When combined with the TX320 GOES satellite transmitter, the CR295X can be used in extremely remote locations.
- Ideal applications include wind energy, rural water, water level/flow, aquaculture, water quality
- Gas Discharge Tube (GDT) protected inputs
- Optimal for measuring one or two simple sensors
- Makes SDI-12, single-ended analog, pulse, switch closure, and bridge measurements
- Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
- Program with LoggerNet, PC400, or Short Cut to fit your setup
- PakBus, Modbus, and SDI-12 protocols supported
Specifications
- -NOTE-
- Note: Additional specifications are listed in the CR200X-Series Specifications Sheet.
- Maximum Scan Rate
- 1 Hz
- Analog Channels
- The single-ended analog inputs can also be used as control ports.
- Analog Channels
- 5 single-ended (no differential)
individually configured
- Pulse Count Channels
- 2
- Switched Excitation Channels
- 2 voltage
- Digital Ports
- Certain digital ports can be used to count switch closures.
- Digital Ports
- 2 I/O
- Communication Ports
- 2 RS-232
- Switched Battery Port
- 1
- Input Voltage Range
- 0 to 2500 mV
- Analog Voltage Accuracy
- ±(0.25% of reading + (1.2 mV)x(offset))
at -40° to +50°C
- Analog Voltage Resolution
- 0.6 mV
- A/D Bits
- 12
- Operating Temperature
- -40° to +50°C
- Power Requirements
- 7 to 16 Vdc
- Typical Current Drain
- ~0.2 mA
(quiescent)
- Typical Current Drain
- ~3 mA
(active)
- Clock Accuracy
- 8.2 min./month
(@ -40° to +50°C)
- Clock Accuracy
- 1 min./month
(@ +25°C)
- Protocols Supported
- PakBus (leaf node only), SDI-12
- Warranty
- 3 years
- Dimensions
- 14.0 x 7.6 x 4.8 cm
(5.5 x 3.0 x 1.9 in.)
- Weight
- 242 g
(8.5 oz)
Memory
- Final Storage
- 512 kB of flash memory for approximately 125,000 data points
- Operating System
- 106 kB of flash memory
- Intermediate Storage
- 8 kB of SRAM for communication buffers, calculations, variables, etc.
Accessories
(11)15598
3 V Coin Cell Lithium Battery CR2025
Orderable15725
CR200(X)-Series Datalogger Compiler and OS on CD
Retired17394
Converter, USB to DB9 Pin (Male) RS-232
Orderable17159
CR200(X)-Series Operator's Manual
Retired16867
Square Connector for CR200 Battery Terminals
Orderable7977
100 Ohm Shunt Resistor Assembly
Orderable1113
Flat-Bladed Screwdriver, 3.0 mm Blade x 60 mm Shaft
End of life10873
Serial Data Cable, 9-Pin Socket (Female) to 9-Pin Pin (Male)
Orderable6044
Grommet for #6 or #8 Screw
Orderable505
Screw #6-32 x .375 Pan Phillips
Orderable8125
Flat-Bladed Screwdriver, 2.5 mm Blade x 50 mm Shaft
Orderable
Related Resources
Documents
Videos and Tutorials

CRBasic | Features
December 16, 2013 (10:36)
Key features of the CRBasic programming language
Watch
Certificates of Calibration
November 16, 2017 (1:05)
Download yours
Watch
CRBasic | Common Errors
December 16, 2013 (11:45)
Identifying and fixing common errors in the CRBasic programming language
Watch
Use LoggerNet to Send a Program and Collect Data (QuickStart Part 3)
August 19, 2015 (5:06)
Viewing data
Watch- View all videos and tutorials