52202

Electrically Heated Rain and Snow Gage
52202

52202

OrderableConfigurable

Electrically Heated Rain and Snow Gage

Lowest cost with a heater.

Configuration

Sign in for option pricing

Select a configuration to add to your quote

Model:
52202
Item Number:
45104
Warranty:
1 year
Lead time:
14 days

Overview

RM Young Heated Rain Gage w/16cm (6.3 Inch) Orifice (-20 to +50C)

The 52202, manufactured by R. M. Young, is a thermostat-controlled, electrically heated, tipping bucket rain gage. You can use it to measure rain, snow, and other frozen precipitation. Its catchment area of 200 cm2 and measurement resolution of 0.1 mm meet the recommendations of the WMO. This heated rain gage is compatible with most Campbell Scientific data loggers, and it is used in environmental monitoring applications.

Key Advantages

Measure Rain, Snow, and Other Frozen Precipitation
Thermostat-controlled gage

Technical Description

The 52202 funnels precipitation into a bucket mechanism that tips when filled to the calibrated level. Each tip is marked by a magnetic reed switch closure that is recorded by a Campbell Scientific data logger pulse count channel.

The 52202 has a thermostat-controlled internal heater that melts snow or other frozen precipitation. This heater requires a reliable source of 24 Vac power. A wall transformer is shipped with the 52202 that plugs into a wall socket to provide the required 24 Vac power.

Benefits

  • High precision—tips at 0.1-mm increments
  • Heating element melts snow and ice for year-round measurements
  • Compatible with many Campbell Scientific data loggers

Specifications

Sensor Type
Tipping bucket with magnetic reed switch

(normally open)

Measurement Uncertainty
2% for up to 25 mm/h

(1 in./h)

Measurement Uncertainty
3% for up to 50 mm/h

(2 in./h)

Rainfall per Tip
0.1 mm

(0.004 in.)

Operating Temperature Range
-20° to +50°C

(heated)

Humidity Range
0 to 100%
Power
18 W @ 24 Vac

(for heater only)

Heater Thermostat Set Point
10°C ±3°C
Contact Rating
24 Vac/dc

(400 mA maximum)

Compliance with Standards
2011/65/EU RoHS Directive
Compliance with Standards
2015/863/EU RoHS Phthalates Amendment
Mounting Pipe
30.5 cm (12 in.) length; 1 inch IPS, aluminum, unthreaded
Catchment Area
200 cm2

(31 in.2)

Orifice Diameter
16 cm

(6.3 in.)

Diameter
18.5 cm

(7.3 in.)

Height
30 cm

(11.8 in.)

Power Plug Weight
0.43 kg

(0.95 lb)

Weight
1.16 kg

(2.55 lb)

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com