PWENC14/16

Prewired Enclosure, 14 x 16 inches
Automated

PWENC14/16

OrderableConfigurable

Prewired Enclosure, 14 x 16 inches

Configuration

Sign in for option pricing

Select a configuration to add to your quote

Model:
PWENC14/16
Item Number:
SP45282
Warranty:
1 year
Lead time:
14 days

Overview

PWENC14/16 Pre-Wired Weather-Resistant 14 X 16 Inch Enclosure

The PWENC14/16 is a prewired, weather-resistant enclosure that is 14 in. wide and 16 in. tall. It starts with the same enclosure used for our ENC14/16, but then is factory configured with up to ten connectors that are attached to the data logger or peripherals within the enclosure. Sensors with the appropriate connector are simply attached to connectors on the outside of the enclosure. The PWENC14/16 includes a basic measurement program (created in ShortCut) for the -PW products sold as part of this system. If a more advanced custom data logger program is required for additional sensors, communications, control, or other needs, an extra fee will be incurred. 

Key Advantages

Saves Work, Prevents Errors
Factory-installed and tested wiring by experienced technicians

Technical Description

The PWENC14/16 can house one data logger, power supply, and one or more peripheral (depending on the peripheral’s footprint). You order the sensors, data logger, power supply, and communication peripherals separately. Compatible sensors, peripheral cables, and solar panels have a –PW extension. 

The PWENC14/16 is shipped with the 7363 enclosure supply kit that consists of desiccant, a humidity indicator card, cable ties, wire tie tabs, putty, grommets, screws, and PVC coupling. Connectors, communication ports, and the enclosure mounting bracket are chosen as options. (See Ordering Info on the web page.)

The PWENC14/16 can be mounted to any of our tripods or towers, or to a user-supplied pipe.

Note: Refer to the Ordering Info on the web page for standard configurations. Nonstandard configurations must be special ordered. It is considered a nonstandard configuration when using a different type, size, or location for any connector, communication port, conduit, cable entry seal, or antenna bulkhead (contact Campbell Scientific for more information).

Benefits

  • Weather resistant to protect instruments
  • Backplate designed so that Campbell Scientific components mount easily and securely
  • Combines flexibility with ease of use
  • Eliminates the task of wiring sensor leads into the data logger’s terminal strips
  • Reduces wiring errors by inexperienced field technicians who are unfamiliar with the equipment
  • Shortens deployment time
  • White, UV-stabilized enclosure reflects solar radiation—reducing temperature gradients inside the enclosure without requiring a separate radiation shield
  • Allows each enclosure in a large network to be similar to the other enclosures
  • Customized options may be purchased

Specifications

Color
White

(Reflects solar radiation, reducing temperature gradients inside the enclosure without requiring a separate radiation shield.)

Construction
Fiberglass-reinforced polyester enclosure with door gasket, external grounding lug, stainless-steel hinge, and lockable hasps
Enclosure Classification
NEMA 4X

(before being modified for cable entry)

Dimensions
35.6 x 40.6 x 14 cm

(14 x 16 x 5.5 in.) internal

Dimensions
38.6 x 33.7 x 17.6 cm

(15.2 x 13.3 x 6.9 in.) internal under the lid space

Dimensions
44.3 x 39.2 x 19.6 cm

(17.8 x 15.4 x 7.7 in.) external

Weight
6 kg

(13 lb)

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com

As a trusted leader in measurement systems for more than 50 years, our top priority at Campbell Scientific has always been to provide the most accurate, reliable data for research and industry.