CR850
CR850
RetiredConfigurableGSAMeasurement and Control Datalogger
Built-in keyboard and display.
Pricing
Configuration
Sign in for option pricing- DISPLAYDISPLAY
- OBSOLETE CR850-ST-SW-NC Measurement & Control Datalogger w/Built-In Keyboard & Display -ST -25 to +50C -SW Standard 3yr Warranty -NC No Calibration CertOBSOLETE
- OBSOLETE CR850-XT-SW-CC Measurement & Control Datalogger w/Built-In Keyboard & Display -XT -30 to +80C -SW Standard 3yr Warranty -CC Calibration CertOBSOLETE
- 0 to +80C -XW 4yr Warr Extension -CC Calibration CertOBSOLETE
- OBSOLETE CR850-XT-SW-NC Measurement & Control Datalogger w/Built-In Keyboard & Display -XT -30 to +80C -SW Standard 3yr Warranty -NC No Calibration CertOBSOLETE
- OBSOLETE CR850-ST-SW-CC Measurement & Control Datalogger w/Built-In Keyboard & Display -ST -25 to +50C -SW Standard 3yr Warranty -CC Calibration CertOBSOLETE
- OBSOLETE CR850-ST-XW-NC Measurement & Control Datalogger w/Built-In Keyboard & Display -ST -25 to +50C -XW 4yr Warr Extension -NC No Calibration CertOBSOLETE
- OBSOLETE CR850-XT-XW-NC Measurement & Control Datalogger w/Built-In Keyboard & Display -XT -30 to +80C -XW 4yr Warr Extension -NC No Calibration CertOBSOLETE
- OBSOLETE CR850-ST-XW-CC Measurement & Control Datalogger w/Built-In Keyboard & Display -ST -25 to +50C -XW 4yr Warr Extension -CC Calibration CertOBSOLETE
- OBSOLETE CR850-ST-SW-NC Measurement & Control Datalogger w/Built-In Keyboard & Display -ST -25 to +50C -SW Standard 3yr Warranty -NC No CalibrationOBSOLETE
- OBSOLETE CR850-ST-SW-NC Measurement & Control Datalogger w/Built-In Keyboard & Display -ST -25 to +50C -SW Standard 3yr Warranty -NC No CalibrationOBSOLETE
Select a configuration to add to your quote
- Model:
- CR850
- Item Number:
- 18788
- Warranty:
- 3 years
- Lead time:
- 14 days
- Compliance:
- needs power supply
Overview
The CR850 is a smaller, research-grade data logger that includes an on-board keyboard display as part of its integrated package. It is intended for smaller configurations in which fewer sensors will be measured. Each CR850 reads input from sensors, then transmits the data via a communication peripheral; most sensors and telecommunication devices are compatible. Multiple CR850s can be configured as a network or units can be deployed individually. This rugged data logger can provide stand-alone operation in harsh, remote environments.
Key Advantages
Research-grade power with built-in keyboard and display
Technical Description
The CR850 consists of measurement electronics encased in a plastic shell with an integrated wiring panel, 16- character keyboard, and display screen. The display can show 8 lines x 21 characters (64 x 128 pixels). Custom menus are supported allowing customers to set up choices within the data logger program that can be initiated by a simple “toggle” or “pick list”. Its keyboard and display screen is used to program the data logger, manually initiate data transfer, and display data.
The CR850 uses an external power supply. Low power consumption allows the it to operate for extended periods on a battery recharged with a solar panel—eliminating the need for AC power. The CR850 suspends execution when primary power drops below 9.6 V, reducing the possibility of inaccurate measurements.
The on-board operating system includes measurement, processing, and output instructions for programming the data logger. The programming language, CRBasic, uses a BASIC-like syntax. Measurement instructions specific to bridge configurations, voltage outputs, thermocouples, and pulse/frequency signals are included. Processing instructions support algebraic, statistical, and transcendental functions for on-site processing. Output instructions process data over time and control external devices.
Benefits
- Integrated keyboard and display screen let you program, manually initiate data transfers, and view data, all on site.
- Ideal applications include wind profiling, weather stations, ETo/agriculture, air quality, soil moisture, water level/stage, aquaculture, vehicle testing, Time Domain Reflectometry, SCADA, and water quality
- Simpler in design, the CR800 and CR850 are easier to program and wire.
- Serial communications with serial sensors and devices supported via I/O port pairs
- Contains custom ASIC chip that expands pulse count, control port, and serial communications capabilities
- Supports PakBus, Modbus, SDI-12, and DNP3 protocols
- Compatible with channel expansion peripherals allowing you to expand your system
- Includes both an CS I/O port and an RS-232 port for connecting communication devices
- Gas Discharge Tube (GDT) protected inputs
- Battery-backed clock that ensures accurate time is maintained while data logger is disconnected from battery power
- Program with LoggerNet, PC400, or Short Cut to fit your setup
Specifications
- -NOTE-
- Note: Additional specifications are listed in the CR800-Series Specifications Sheet.
- Operating Temperature Range
- -25° to +50°C
(standard)
- Operating Temperature Range
- Non-condensing environment
- Maximum Scan Rate
- 100 Hz
- Analog Inputs
- 6 single-ended or 3 differential
(individually configured)
- Pulse Counters
- 2
- Voltage Excitation Terminals
- 2
(VX1, VX2)
- Communications Ports
- CS I/O
- Communications Ports
- RS-232
- Switched 12 Volt
- 1 terminal
- Digital I/O
- Certain digital ports can be used to count switch closures.
- Digital I/O
- 4 I/Os or 2 RS-232 COM
I/O ports can be paired as transmit and receive for measuring smart serial sensors. - Input Limits
- ±5 V
- Analog Voltage Accuracy
- ±(0.06% of reading + offset)
at 0° to 40°C
- ADC
- 13-bit
- Power Requirements
- 9.6 to 16 Vdc
- Real-Time Clock Accuracy
- ±3 min. per year
(Correction via GPS optional.)
- Internet Protocols
- FTP, HTTP, XML POP3, SMTP, Telnet, NTCIP, NTP
- Communication Protocols
- PakBus, Modbus, DNP3, SDI-12, SDM
- Idle Current Drain, Average
- 1 mA
(@ 12 Vdc)
- Active Current Drain, Average
- 1 to 16 mA
(1 Hz sample rate @ 12 Vdc without RS-232 communication)
- Active Current Drain, Average
- 16 mA
(100 Hz sample rate @ 12 Vdc without RS-232 communication)
- Active Current Drain, Average
- 28 mA
(100 Hz sample rate @ 12 Vdc with RS-232 communication)
- Dimensions
- 24.1 x 10.4 x 5.1 cm
(9.5 x 4.1 x 2 in.)
- Weight
- 0.7 kg
(1.5 lb)
Accessories
(6)SC32B
Optically Isolated RS-232 Interface
OrderableSC-USB
Optically Isolated USB Interface
Retired17394
Converter, USB to DB9 Pin (Male) RS-232
OrderableSC110
Two Cables, RS-232 to Data Logger Control Port
OrderableSC-CPI
Datalogger-to-CPI Interface
Retired27373
14 to 28 AWG 5-Position Terminal Connector with Lever Nut
Orderable
Related Resources
Case Studies

New Mexico: Meteorological Monitoring at a Mine
Upgrading measurement system at mining site
Questa, New Mexico, USA
April 11, 2017
View
Mexico: Six Airports Get Automatic Weather Stations
Weather monitoring at airports
Airports in six cities in Mexico
April 30, 2009
View
Louisiana: Sinkhole Monitoring
Early warning of catastrophic ground movement
Bayou Corne, Louisiana, USA
November 12, 2018
View
New Zealand: Coal Mine Water Quality Monitoring
Monitoring water quality in coal-mine runoff
West Coast of New Zealand
May 15, 2009
View- View all case studies
Documents
Videos and Tutorials

LoggerLink Software | An Introduction
January 29, 2013 (12:11)
A mobile app for iOS and Android
Watch
CRBasic in the Real World Part 5: Changing the Sensor Used in a Program and Program Versioning
September 29, 2023 (5:42)
How to change a program from one SDI-12 sensor to another and track changes in the program.
Watch
Certificates of Calibration
November 16, 2017 (1:05)
Download yours
Watch
Hughes 9502 Inmarsat BGAN Satellite IP Terminal
October 19, 2016 (13:08)
Making an Internet connection to a datalogger
Watch- View all videos and tutorials