EC150
EC150
OrderableConfigurableGSACO2/H2O Open-Path Gas Analyzer
Pricing
Configuration
Sign in for option pricing- w/EC150 Carrying Case No CR6 Mounting CSAT3A & Gas Analyzer w/Sonic Carrying Case w/Basic BarometerEC150-GC-NM-SS-SC-BB
- w/EC150 Carrying Case No CR6 Mounting CSAT3A & Gas Analyzer No Sonic Case w/Basic BarometerEC150-GC-NM-SS-NC-BB
- w/EC150 Carrying Case No CR6 Mounting Gas Analyzer Only No Sonic Case w/Basic BarometerEC150-GC-NM-GH-NA-BB
- No EC150 Case No CR6 Mounting Gas Analyzer Only No Sonic Case w/Basic BarometerEC150-NG-NM-GH-NA-BB
- No EC150 Case No CR6 Mounting CSAT3A & Gas Analyzer w/Sonic Carrying Case w/Basic BarometerEC150-NG-NM-SS-SC-BB
- No EC150 Case No CR6 Mounting CSAT3A & Gas Analyzer No Sonic Case w/Basic BarometerEC150-NG-NM-SS-NC-BB
- w/EC150 Carrying Case No CR6 Mounting Gas Analyzer Only No Sonic Case w/Enhanced BarometerEC150-GC-NM-GH-NA-EB
- w/EC150 Carrying Case No CR6 Mounting CSAT3A & Gas Analyzer No Sonic Case w/Enhanced BarometerEC150-GC-NM-SS-NC-EB
- w/EC150 Carrying Case No CR6 Mounting CSAT3A & Gas Analyzer w/Sonic Carrying Case w/Enhanced BarometerEC150-GC-NM-SS-SC-EB
- No EC150 Case No CR6 Mounting Gas Analyzer Only No Sonic Case w/Enhanced BarometerEC150-NG-NM-GH-NA-EB
Select a configuration to add to your quote
- Model:
- EC150
- Item Number:
- 45304
- Warranty:
- 3 years or 17,500 hours
- Lead time:
- 14 days
Overview
Campbell Scientific’s EC150 is an open-path analyzer specifically designed for eddy-covariance carbon and water flux measurements. As a stand-alone analyzer, it simultaneously measures absolute carbon-dioxide and water-vapor densities, air temperature, and barometric pressure. With the optional CSAT3A sonic anemometer head, three-dimensional wind speed and sonic air temperature are measured.
Key Advantages
Use as part of open-path eddy-covariance systems or as a stand-alone IRGA
Technical Description
The CSAT3A has the following outputs:
- Ux (m/s)*
- Uy (m/s)*
- Uz (m/s)*
- Sonic Temperature (°C)*
- Sonic Diagnostic*
The EC150 has the following outputs:
- CO2 Density (mg/m3)
- H2O Density (g/m3)
- Gas Analyzer Diagnostic
- Ambient Temperature (°C)
- Atmospheric Pressure (kPa)
- CO2 Signal Strength
- H2O Signal Strength
- Source Temperature (°C)
*The first five outputs require the CSAT3A Sonic Anemometer Head.
Benefits
- New conformal coating helps protect sonic transducers in corrosive environments
- Unique optical configuration gives a slim aerodynamic shape with minimal wind distortion
- Analyzer and sonic anemometer measurements are synchronized by a common set of electronics
- Maximum output rate of 60 Hz with 20 Hz bandwidth
- Low power consumption; suitable for solar power applications
- Low noise
- Measurements are temperature compensated without active heat control
- Angled windows to shed water and are tolerant to window contamination
- Field rugged
- Field serviceable
- Factory calibrated over wide range of CO<sub>2</sub>, H<sub>2</sub>O, pressure, and temperature in all combinations encountered in practice
- Extensive set of diagnostic parameters
- Fully compatible with Campbell Scientific dataloggers; field setup, configuration, and field zero and span can be accomplished directly from the datalogger
- Speed of sound determined from three acoustic paths; corrected for crosswind effects
- Innovative signal processing and transducer wicks considerably improve performance of the anemometer during precipitation events
Specifications
- Operating Temperature Range
- -30° to +50°C
- Calibrated Pressure Range
- 70 to 106 kPa
- Input Voltage Range
- 10 to 16 Vdc
- Power
- 5 W
(steady state and power up) at 25⁰C
- Measurement Rate
- 60 Hz
- Output Bandwidth
- 5, 10, 12.5, or 20 Hz
(user-programmable)
- Output Options
- SDM, RS-485, USB, analog
(CO2 and H2O only)
- Auxiliary Inputs
- Air temperature and pressure
- Gas Analyzer/Sonic Volume Separation
- 5.0 cm
(2.0 in.)
- Warranty
- 3 years or 17,500 hours of operation
(whichever comes first)
- Cable Length
- 3 m (10 ft) from EC150 and CSAT3A to EC100
- Weight
- 2.0 kg
(4.4 lb) for EC150 head and cables
- Weight
- 1.7 kg
(3.7 lb) for CSAT3A head and cables
- Weight
- 3.2 kg
(7.1 lb) for EC100 electronics
Gas Analyzer
- Path Length
- 15.37 cm
(6.05 in.)
A temperature of 20°C and pressure of 101.325 kPa was used to convert mass density to concentration.
Gas Analyzer - CO<sub>2</sub> Performance
- -NOTE-
- A temperature of 20°C and pressure of 101.325 kPa was used to convert mass density to concentration.
- Accuracy
- Assumes the following:
the gas analyzer was properly zero and spanned using the appropriate standards; CO2 span concentration was 400 ppm; H2O span dewpoint was at 12°C (16.7 ppt); zero/span temperature was 25°C; zero/span pressure was 84 kPa; subsequent measurements made at or near the span concentration; temperature is not more than ±6°C from the zero/span temperature; and ambient temperature is within the gas analyzer operating temperature range.
- Accuracy
- 1%
(standard deviation of calibration residuals)
- Precision RMS (maximum)
- 0.2 mg/m3
(0.15 µmol/mol)
Nominal conditions for precision verification test: 25°C, 86 kPa, 400 μmol/mol CO2, 12°C dewpoint, and 20 Hz bandwidth. - Calibrated Range
- 0 to 1,000 μmol/mol
(0 to 3,000 µmol/mole available upon request.)
- Zero Drift with Temperature (maximum)
- ±0.55 mg/m3/°C
(±0.3 μmol/mol/°C)
- Gain Drift with Temperature (maximum)
- ±0.1% of reading/°C
- Cross Sensitivity (maximum)
- ±1.1 x 10-4 mol CO2 /mol H2O
Gas Analyzer - H<sub>2</sub>O Performance
- -NOTE-
- A temperature of 20°C and pressure of 101.325 kPa was used to convert mass density to concentration.
- Accuracy
- Assumes the following:
the gas analyzer was properly zero and spanned using the appropriate standards; CO2 span concentration was 400 ppm; H2O span dewpoint was at 12°C (16.7 ppt); zero/span temperature was 25°C; zero/span pressure was 84 kPa; subsequent measurements made at or near the span concentration; temperature is not more than ±6°C from the zero/span temperature; and ambient temperature is within the gas analyzer operating temperature range.
- Accuracy
- 2%
(standard deviation of calibration residuals)
- Precision RMS (maximum)
- 0.004 g/m3 mmol/mol
(0.006 mmol/mol)
Nominal conditions for precision verification test: 25°C, 86 kPa, 400 μmol/mol CO2, 12°C dewpoint, and 20 Hz bandwidth. - Calibrated Range
- 0 to 72 mmol/mol
(38°C dewpoint)
- Zero Drift with Temperature (maximum)
- ±0.037 g/m3/°C
(±0.05 mmol/mol/°C)
- Gain Drift with Temperature (maximum)
- ±0.3% of reading/°C
- Cross Sensitivity (maximum)
- ±0.1 mol H2O/mol CO2
Sonic Anemometer - Accuracy
- Offset Error
- < ±8.0 cm s-1
(for ux, uy)
- Offset Error
- < ±4.0 cm s-1
(for uz)
- Offset Error
- ±0.7° while horizontal wind at 1 m s-1
(for wind direction)
- Gain Error
- < ±2% of reading
(for wind vector within ±5° of horizontal)
- Gain Error
- < ±3% of reading
(for wind vector within ±10° of horizontal)
- Gain Error
- < ±6% of reading
(for wind vector within ±20° of horizontal)
- Measurement Precision RMS
- 1 mm s-1
(for ux, uy)
- Measurement Precision RMS
- 0.5 mm s-1
(for uz)
- Measurement Precision RMS
- 0.025°C
(for sonic temperature)
- Measurement Precision RMS
- 0.6°
(for wind direction)
- Speed of Sound
- Determined from 3 acoustic paths
(corrected for crosswind effects)
- Rain
- Innovative ultrasonic signal processing and user-installable wicks considerably improve the performance of the anemometer under all rain events.
Ambient Temperature
- Manufacturer
- BetaTherm 100K6A1IA
- Total Accuracy
- ±0.15°C
(-30°C to +50°C)
Accessories
(22)CABLEPCBL
2-Conductor 16 AWG Power Cable
OrderableCABLE4CBL
4-Conductor 22 AWG Cable with Drain
OrderableCR1000KD
Keyboard/Display for CR1000(X), CR800, or CR6
Orderable33288
8 GB microSD Flash SLC Memory Card
Retired17752
USB Memory Card Reader/Writer
Orderable26390
Zero and Span Shroud Kit for the IRGASON or EC150
Orderable27278
IRGASON and EC150 Lab Stand Kit
Orderable31022
Zero Air Generator
OrderableEasyFlux DL
Eddy-Covariance Data Logger Program
OrderableEasyFlux WebH
EasyFlux Web Software, Campbell Scientific-Hosted
Retired27158
2 GB microSD Flash SLC Memory Card
Orderable38476
16 GB microSD Flash aMLC Memory Card
Orderable10080
Thermocouple Cover for CSAT3, CSAT3B, or IRGASON
Orderable31423
Fine-Wire Thermocouple Cover Backplate
OrderableFW05
Type E Fine-Wire Thermocouple with 0.0005 in. Diameter
OrderableFW/ENC
Fine-Wire Thermocouple Carrying Case (hold four thermocouples)
OrderableFWC
Connector Cable for Fine-Wire Thermocouples
OrderableEasyFlux WebS
EasyFlux Web Software, Self-Hosted
RetiredEasyFlux PC
Eddy-Covariance Post-Processing PC Software
OrderableCABLE2TP
22 AWG, 2-Twisted Pair Cable with Drain
OrderableCABLE3TP
24 AWG, 3-Twisted Pair Cable with Drain
OrderableFluoreSens 10
Sun-Induced Chlorophyll Fluorescence (SIF) System
Orderable
Related Resources
Case Studies
Documents
- Technical Paper
Molecular Sieve CO2 and H2O Scrubbing Solution
September 2017
View Document - Technical Paper
EC150, IRGASON, or EC155: Which CO2 and H2O Eddy-Covariance System Is Best for My Application?
January 2017
View Document - Technical Paper
Eddy Covariance Hardware Troubleshooting — Preparing for a Site Visit
June 2026
View Document - Document
Influence of Open-path Gas Analyzer Flow Distortion on Ultrasonic Wind Measurements
View Document - View all documents