Overview
The NR01, manufactured by Hukseflux and cabled for use with Campbell Scientific data loggers, is a research-grade net radiometer that measures the energy balance between incoming short-wave and long-wave infrared radiation versus surface-reflected short-wave and outgoing long-wave infrared radiation. Our data loggers measure the NR01's output and control its internal heater. This net radiometer offers a professional solution for scientific-grade energy balance studies.
Note: NR01 radiometers with a serial number less than 2313 used the pn 21271 fitting. NR01 radiometers with a serial number greater than 2312 do not need the pn 21271 fitting.
Key Advantages
Robust 4-way radiometer that requires little maintenance
Technical Description
The NR01 consists of a pyranometer and pyrgeometer pair that faces upward and a complementary pair that faces downward. The pyranometers and pyrgeometers measure short-wave and far infrared radiation, respectively.
The NR01 includes an on-board RTD to measure the radiometer’s internal temperature and a 1-W heater that minimizes the formation of dew and melts frost. To reduce current drain, a relay is typically used to turn on the heater only when the solar radiation is less than 20 W/m2.
Campbell Scientific’s CR6 and CR3000 dataloggers can directly measure this radiometer. A CR1000 can also be used, but a 4WPB100 module is required to measure the internal RTD.
Benefits
- Internal RTD provides temperature compensation of measurements
- Research-grade performance
- Internal 1-W heater reduces formation of dew and melts frost
- Separate outputs of short-wave and long-wave infrared radiation for better accuracy and more thorough quality assurance
- Robust—only requiring limited maintenance
Specifications
- Sensor
- Hukseflux’s SR01 ISO-class, thermopile pyranometers, IR01 pyrgeometers, PT100 RTD
- Measurement Description
- Measures incoming and outgoing short-wave and long-wave radiation
- Response Time
- 18 s
- Sensitivity
- 10 to 40 μV W-1 m2
- Expected Output Range
- -0.1 to +50 mV
- Expected Accuracy for Daily Totals
- ±10%
- Heater
- 90 ohm, 1.6 W
(at 12 Vdc)
- Operating Temperature Range
- -40° to +80°C
- Heater Current Drain
- ~140 mA
- Dimensions
- 26.3 x 11.3 x 12.1 cm
(10.4 x 4.4 x 4.8 in.)
- Weight
- 1.3 kg
(2.9 lb) with 5 m (16.4 ft) cable
- Weight
- 0.9 kg
(2 lb) sensor only
Pyranometer
- Spectral Range
- 305 to 2800 nm
Pyrgeometer
- Spectral Range
- 4500 to 50,000 nm