CS547A
CS547A
OrderableConfigurableGSAWater Conductivity and Temperature Probe
Monitors the electrical conductivity (EC) and temperature of water.
Pricing
Configuration
Sign in for option pricing- w/5m (17ft) per Sensor -PF w/Ferrules on Wires Cable Weighted 2.7oz-5m
- w/5m (17ft) per Sensor -PF w/Ferrules on Wires No Weight on Cable-5m
- w/10m (33ft) per Sensor -PF w/Ferrules on Wires Cable Weighted 2.7oz-10m
- w/10m (33ft) per Sensor -PF w/Ferrules on Wires No Weight on Cable-10m
- w/15m (50ft) per Sensor -PF w/Ferrules on Wires Cable Weighted 2.7oz-15m
- w/15m (50ft) per Sensor -PF w/Ferrules on Wires No Weight on Cable-15m
- w/25m (83ft) per Sensor -PF w/Ferrules on Wires Cable Weighted 2.7oz-25m
- w/25m (83ft) per Sensor -PF w/Ferrules on Wires No Weight on Cable-25m
- w/30m (100ft) per Sensor -PF w/Ferrules on Wires Cable Weighted 2.7oz-30m
- w/60m (200ft) per Sensor -PF w/Ferrules on Wires Cable Weighted 2.7oz-60m
Select a configuration to add to your quote
- Model:
- CS547A
- Item Number:
- 45245
- Warranty:
- 1 year
- Lead time:
- 14 days
Overview
The CS547A probe monitors the electrical conductivity (EC) and temperature of water. EC is measured with three cylindrical stainless-steel electrodes mounted in an epoxy housing. The electrode configuration eliminates ground loop problems associated with sensors in electrical contact with earth ground. The electrodes are ac coupled, and a bipolar excitation is applied. This reduces electrochemical reactions, minimizes corrosion, and extends the probe’s life. Temperature is sensed with a thermistor.
The CS547A is shipped with a cell constant calibrated in a 0.01 molal KCl solution at 25°C. The solution has an EC of 1.408 mS cm-1.
Key Advantages
Epoxy housing is durable and easy to clean
Technical Description
The CS547A measures temperature with a thermistor. Electrical conductivity (EC) is measured with three cylindrical stainless-steel electrodes mounted in an epoxy housing. The electrode configuration eliminates ground loop problems associated with sensors in electrical contact with earth ground. The electrodes are ac coupled, and the data logger applies a bipolar excitation. This process reduces electrochemical reactions, minimizes corrosion, and extends the probe’s life.
The CS547A is easy to clean and resistant to corrosion. It has rounded ends to facilitate installation and removal. The CS547A is shipped with a cell constant calibrated in a 0.01 molal KCl solution at 25°C. The solution has an EC of 1.408 mS cm-1.
Benefits
- Compatible with most Campbell Scientific data loggers
- Easy to clean
- Corrosion resistant
- Rounded ends facilitate installation and removal
- Compatible with AM16/32-series multiplexers allowing measurement of multiple sensors
- Weighted option available for stand-alone submersion
Specifications
- Output
- Analog
(requires A547 interface)
- Conductivity Measurement Range
- ~0.005 to 7 mS/cm
- Temperature Measurement Range
- 0° to 50°C
- Conductivity Accuracy
- The EC accuracy is in a KCl and Na2SO4, NaHCO3, and NaCl Standard Solutions @ 25°C.
- Conductivity Accuracy
- ±5% of reading
(for 0.44 to 7.0 mS cm-1 range)
- Temperature Polynomial Linearization Error
- Typically < 0.1°C
(over 0° to 48°C)
- Thermistor Interchangeability
- Typically < 0.2°C
(over 0° to 50°C)
- Wetted Materials
- Epoxy housing, 316 stainless-steel rings, polyurethane cable
- pH Operating Range
- Solution pH of less than 3.0 or greater than 9.0 may damage the stainless-steel housing.
- Operating Temperature Range
- 0° to 50°C
- Depth Rating
- 305 m
(1000 ft) maximum
- Dimensions
- 8.9 x 2.54 x 1.9 cm
(3.5 x 1 x 0.75 in)
- Weight
- 45 g
(2 oz)
- Weight
- 120 g
(4.2 oz) with 1.22 m (4 ft) cable
- Weighted Cable Weight
- 80 g
(2.8 oz)