LI200X-L

Silicone Pyranometer with Fixed Daylight Calibration
Hoa Pham

LI200X-L

End of lifeConfigurable

Silicone Pyranometer with Fixed Daylight Calibration

Model:
LI200X-L
Item Number:
8189
Warranty:
1 year
Lead time:
21 days
Compliance:
requires LI2003S and CM225

Overview

LI200X-L LI-COR Pyranometer, Fixed Calibration

The LI200X, manufactured by LI-COR, is a pyranometer that monitors sun plus sky radiation. It connects directly to our data loggers, and is used extensively in solar, agricultural, and meteorological applications.

Key Advantages

Accurate, Compatible
Connects directly to most Campbell dataloggers

Technical Description

The LI200X uses a silicon photovoltaic detector mounted in a cosine-corrected head to provide solar radiation measurements. Calibrated against an Eppley precision spectral pyranometer (PSP), the LI200X accurately measures sun plus sky radiation for the spectral range of 400 to 1100 nm. Sensors calibrated to this spectral range should not be used under vegetation or artificial lights.

The LI200X includes an epoxy-encased completion circuit in its cable. This completion circuit standardizes the sensor's sensor's calibration, allowing individual sensors to be interchanged without altering multiplier and offset values.

The standard output is 0.005 mV per W m-2, which provides a signal of 5 mV in full sunlight (1000 W m-2). All of our data loggers, except the CR200(X) series, can measure this output.

Benefits

  • Compatible with most Campbell Scientific data loggers
  • Calibrated for the daylight spectrum (400 to 1100 nm)
  • Completion circuit in its cable standardizes calibration, allowing sensors to be interchanged without altering multiplier and offset values

Specifications

Light Spectrum Waveband
400 to 1100 nm
Accuracy
Absolute error in natural daylight is ±5% maximum

(±3% typical)

Sensitivity
0.2 kW m-2 mV-1
Linearity
Maximum deviation of 1% up to 3000 W m-2
Shunt Resistor
Adjustable, 40.2 to 90.2 ohm

(factory set to the above sensitivity)

Stability
< ±2% change over a 1 year period
Response Time
10 μs
Temperature Dependence
0.15% per °C

(maximum)

Cosine Correction
Cosine corrected up to 80° angle of incidence
Operating Temperature Range
-40° to +65°C


The overmolding that protects the completion circuit in the cable may crack if the temperature drops below -40°C.

Relative Humidity Range
0 to 100%
Detector
High stability silicon photovoltaic detector

(blue enhanced)

Sensor Housing
Weatherproof anodized aluminum case with acrylic diffuser and stainless-steel hardware
Diameter
2.38 cm

(0.94 in.)

Height
2.54 cm

(1.00 in.)

Weight
28 g

(1 oz)