Granite 9
Granite 9
OrderableConfigurableGSAHigh-Capacity, High-Speed Data Acquisition System
Pricing
Configuration
Sign in for option pricing- Standard DutyGRANITE9-SD
- Extended DutyGRANITE9-XD
Select a configuration to add to your quote
- Model:
- Granite 9
- Item Number:
- GRANITE9
- Warranty:
- 3 years
- Lead time:
- 60 days
Overview
The Granite™9 and Granite™10 are the most computationally powerful data acquisition devices from Campbell Scientific. As an all-digital measurement and control DAQ, the Granite 9 is designed as the core of the data acquisition network, integrating with all GRANITE™ measurement modules, including the Volt 108, Volt 116, Temp 120, and VWire 305.
Key Advantages
Designed for structural health and environmental monitoring projects where multiple high-speed channels with expandable capabilities may be required
Technical Description
The Granite 9 enables you to perform the following:
- Standard measurement functions
- Advanced math and processing functions
- Control functions
A complete GRANITE system installation may include the following components:
- Granite™Chassis
- Granite 9
- Power source (mains or solar)
- Software
Benefits
- Traditional network connections via Ethernet port
- EPI port switch for high-speed connection to all GRANITE measurement modules
- Onboard storage of streaming data with 2 GB of DDR3 SDRAM and a 64 GB solid-state hard drive (SSD)
- Built-in GPS for network synchronization
Specifications
- -NOTE-
- Additional specifications are listed in the GRANITE 9 Specifications.
- Maximum Program Scan Rate
- 10 kHz
- Measurement Module Synchronization
- ±5 µs
(CPI)
- Measurement Module Synchronization
- ±50 ns
(EPI)
- GPS Synchronization
- ±200 ns
- Maximum Number of Measurement Modules
- 15 + 15 + 15
- Power Requirements
- 9.6 to 32 Vdc
(voltage input)
- Power Requirements
- 10 to 18 Vdc for battery input (BAT)
- Real-Time Clock Accuracy
- ±3 min. per year
- Operating Temperature Range
- -40° to +70°C
(standard)
- Operating Temperature Range
- -55° to +85°C
(extended)
- Operating Temperature Range
- Non-condensing environment
- Case Material
- Stainless steel 304 and aluminum 6061
- Universal Inputs
- 12 individually configured inputs for analog or digital functions
- Pulse Counters
- 12 (U1 to U12)
- Voltage Excitation Terminals
- 12 (U1 to U12)
- Communications Ports
- Ethernet
- Communications Ports
- USB Micro B
- Communications Ports
- USB host
- Communications Ports
- CS I/O
- Communications Ports
- 0 to 5 V serial
- Communications Ports
- SDI-12
- Communications Ports
- RS-485
- Communications Ports
- RS-422
- Communications Ports
- CPI/RS-232
- Communications Ports
- EPI
- Data Storage Ports
- microSD
- Data Storage Ports
- USB host
- Digital I/O
- 8 terminals (C1 to C8) configurable for digital input and output.
Terminals are configurable in pairs for 5 V or 3.3 V logic for some functions.
- Analog Voltage Accuracy
- Accuracy specifications do not include sensor or measurement noise.
- Analog Voltage Accuracy
- ±(0.04% of measurement + offset) at 0° to 40°C
- Analog Voltage Accuracy
- ±(0.06% of measurement + offset) at -40° to +70°C
- Analog Voltage Accuracy
- ±(0.08% of measurement + offset) at -55° to +85°C
(extended temperature range)
- ADC
- 24-bit
- Internet Protocols
- Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, Telnet, HTTP(S), SFTP, FTP(S), POP3/TLS, NTP, SMTP/TLS, SNMPv3, CS I/O IP
- Communication Protocols
- CPI, EPI PakBus, PakBus Encryption, SDM, SDI-12, Modbus RTU / ASCII / TCP, DNP3, custom user definable over serial, UDP, NTCIP, NMEA 0183, I2C, SPI
- Warranty
- 3 years standard (against defects in materials and workmanship)
- Warranty
- Optional: An additional 2 years (against defects in materials and workmanship), bringing the total to 5 years
- Battery-backed SRAM for CPU Usage & Final Storage
- 4 MB
- Data Storage
- 4 MB SRAM + 128 MB NOR flash
(Storage expansion of up to 16 GB with removable microSD flash memory card.)
- Data Storage
- 64 GB SSD
- Idle Current Drain, Average
- Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
- Idle Current Drain, Average
- < 1 mA
- Active Current Drain, Average
- Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
- Active Current Drain, Average
- ~6 W
- Active Current Drain, Average
- 255 mA input
(24 V input)
- Active Current Drain, Average
- 495 mA input
(12 V input)
- Static Vibrating-Wire Measurements
- Not supported
- Dimensions
- 21.4 x 12.0 x 5.0 cm
(8.4 x 4.7 x 2.0 in.)
Additional clearance required for cables and leads. - Weight
- 1.0 kg
(2.2 lb)
Ships With
(1)- Orderable
Related Resources
Case Studies
Documents
Videos and Tutorials
View Data Tutorial
July 20, 2016
Watch
Double-Precision Calculations
February 4, 2022 (5:50)
Explains the differences between Single-Precision and Double-Precision calculations.
Watch
Fundamentals of CRBasic Programming Part 6: Loops
October 21, 2022 (8:54)
Using For/Next and Do loops to simplify a program performing repetitive tasks.
Watch
Using RTMC Pro
October 31, 2023 (5:44)
How to create a screen in RTMC Pro
Watch- View all videos and tutorials