Overview

Measurement & Control Data Acquisition System

The Granite™6 DAQ is a powerful core component for your complete data acquisition system. The Granite 6 provides fast communication, low power requirements, built-in USB and Wi-Fi, modular design, and high analog input accuracy and resolution. It uses universal (U) terminals to allow a connection to virtually any sensor—analog, digital, or smart. The multipurpose DAQ is also capable of measuring static vibrating wire measurements.

Learn about our patented VSPECT™ spectral-analysis technology at our VSPECT Essentials web resource.

The dynamic vibrating wire measurement technique is protected under U.S. Patent No. 8,671,758, and the vibrating wire spectral-analysis technology (VSPECT) is protected under U.S. Patent No. 7,779,690.

Key Advantages

Rugged for the Field, Refined for the Lab
Flexible, precise, accurate

Technical Description

The Granite 6 provides extreme measurement versatility, has multiple communications options, processes sensor responses to engineering units, performs calculations, generates alarms, and controls external devices. Data are stored in onboard, nonvolatile memory awaiting transfer to the end user via direct or remote access. The Granite 6 can generate real-time or event-driven data tables. These data can be further processed with high-level math functions and statistical summaries such as averages, standard deviations, and rainflow histograms.

Benefits

  • Operational in extreme environments with a standard operating range of -40° to +70°C <!--and an extended operating range of -55° to +85°C-->
  • USB and built-in Wi-Fi for easy connection to PC
  • Universal terminals configurable for analog or digital, input or output
  • Supports static vibrating wire measurements using Campbell Scientific’s patented VSPECT spectral analysis technology
  • Industry leader for high-resolution measurement needs
  • USB host facilitates additional memory in large data applications

Specifications

-NOTE-
Additional specifications are listed in the GRANITE 6 Specifications.
Pulse Counters
12 (U1 to U12)
Voltage Excitation Terminals
12 (U1 to U12)
Universal Inputs
12 individually configured inputs for analog or digital functions
Case Material
Stainless steel 304 and aluminum 6061
Operating Temperature Range
-40° to +70°C

(standard)

Operating Temperature Range
Non-condensing environment
Communications Ports
Ethernet
Communications Ports
USB Micro B
Communications Ports
USB host
Communications Ports
CS I/O
Communications Ports
0 to 5 V serial
Communications Ports
SDI-12
Communications Ports
RS-485
Communications Ports
RS-422
Communications Ports
CPI/RS-232
Data Storage Ports
microSD
Data Storage Ports
USB host
Digital I/O
16 terminals (C1 to C4, U1 to U12) configurable for digital input and output.

Terminals are configurable in pairs for 5 V or 3.3 V logic for some functions.

Analog Voltage Accuracy
Accuracy specifications do not include sensor or measurement noise.
Analog Voltage Accuracy
±(0.04% of measurement + offset) at 0° to 40°C
Analog Voltage Accuracy
±(0.06% of measurement + offset) at -40° to +70°C
ADC
24-bit
Power Requirements
16 to 32 Vdc for charger input (CHG)
Power Requirements
10 to 16 Vdc for battery input (BAT)
Real-Time Clock Accuracy
±3 min. per year (optional GPS correction to ±10 µs; 5.7 ppm)
Internet Protocols
Ethernet, PPP, RNDIS, ICMP/Ping, Auto-IP (APIPA), IPv4, IPv6, UDP, TCP, TLS (v1.2), DNS, DHCP, SLAAC, Telnet, HTTP(S), SFTP, FTP(S), POP3/TLS, NTP, SMTP/TLS, SNMPv3, CS I/O IP
Communication Protocols
CPI, PakBus, PakBus Encryption, SDM, SDI-12, Modbus RTU / ASCII / TCP, DNP3, custom user definable over serial, UDP, NTCIP, NMEA 0183, I2C, SPI
Warranty
3 years standard (against defects in materials and workmanship)
Warranty
Optional: An additional 2 years (against defects in materials and workmanship), bringing the total to 5 years
Battery-backed SRAM for CPU Usage & Final Storage
4 MB
Data Storage
4 MB SRAM + 72 MB flash

(Storage expansion of up to 16 GB with removable microSD flash memory card.)

Idle Current Drain, Average
Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
Idle Current Drain, Average
< 1 mA
Active Current Drain, Average
Assumes 12 Vdc on BAT terminals; add 2 mA if using CHG terminals.
Active Current Drain, Average
3 mA

(1 Hz scan)

Active Current Drain, Average
67 mA

(20 Hz scan)

Static Vibrating Wire Measurements
Supported
Dimensions
21.4 x 12.0 x 5.0 cm

(8.4 x 4.7 x 2.0 in.)
Additional clearance required for cables and leads.

Weight
0.86 kg

(1.9 lb)

Maximum Program Scan Rate
1 kHz
Measurement Module Synchronization
±5 µs

(CPI)

GPS Synchronization
±20 µs
Maximum Number of Measurement Modules
15
Input Limits
±5 V

Ships With

(8)

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com

As a trusted leader in measurement systems for more than 50 years, our top priority at Campbell Scientific has always been to provide the most accurate, reliable data for research and industry.