CPEC306
CPEC306
OrderableConfigurableGSAExpandable Closed-Path Eddy-Covariance System with EC155 and Pump Module
Pricing
Configuration
Sign in for option pricing- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/o VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) w/CR6-NA w/o VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/o VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- w/EC155 & Pump Module (-30 to +50C) Wired for CR6 w/o VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Casew/EC155
- 5 & Pump Module (-30 to +50C) w/CR6-WIFI w/VOLT116 w/Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Case5
- 5 & Pump Module (-30 to +50C) w/CR6-WIFI w/VOLT116 No Keyboard/Display w/CSAT3A Harsh w/Sonic Carrying Case w/EC155 Carrying Case5
Select a configuration to add to your quote
- Model:
- CPEC306
- Item Number:
- 45298
- Warranty:
- 1 year
- Lead time:
- 14 days
Overview
The CPEC306 with EasyFlux® is a turn-key, closed-path eddy-covariance (EC) flux system for long-term monitoring of atmospheric-biosphere exchanges of carbon dioxide, water vapor, heat, and momentum. A complete system consists of a closed-path gas analyzer (EC155 closed-path gas analyzer), sonic anemometer (CSAT3A sonic anemometer), data logger (CR6 datalogger), sample pump, and accommodations for a Granite™ Volt 116 allowing for additional sensors.
The gas analyzer’s intake design and small sample cell volume (5.9 mL) provide excellent frequency response (4.3 Hz cutoff frequency) with low total system power (12 W). Additionally, the vortex intake (United States Patent No. 9,217,692) greatly reduces maintenance and maintains frequency response compared to traditional inline filters.
Key Advantages
Provides additional ports without automatic zero and span
Technical Description
The gas analyzer’s small sample cell volume (5.9 mL) minimizes the sample residence time (50 ms at the system’s nominal flow rate, 7 LPM). This gives excellent frequency response (5.8 Hz half-power bandwidth) with low total system power (12 W).
Eddy-Covariance Measurements
CO2 and H2O are measured with an EC155 Closed-Path Gas Analyzer. Three-dimensional wind speed and sonic air temperature are measured with a CSAT3A sonic anemometer head.
CPEC306 System Enclosure
The CPEC306 has two enclosures: a fiberglass enclosure that houses the CR6 datalogger, pump module, and optional Granite Volt 116, and the EC100 enclosure for data processing.
CPEC306 Pump Module
The pump module, a standard component of the CPEC306 system, consists of a small dual-head diaphragm pump with a brushless dc motor mounted inside a fiberglass enclosure. An integral cable connects the pump module to the CPEC306 system enclosure, which provides power, temperature measurement and control, pressure measurement, and pumping speed measurement and control.
Benefits
- New conformal coating helps protect sonic transducers in corrosive environments
- Expandable, mid-level system with CR6 datalogger processing power
- Suitable for sites with many sensors and either a short or tall tower
- Simple design for easier troubleshooting
Specifications
- Operating Temperature Range
- -30° to +50°C
- Input Voltage Range
- 10.5 to 16.0 Vdc
- Power
- 12 W
(typical)
- Power
- 35 W
(maximum, at cold startup)
System Enclosure
- Dimensions
- 54 x 44.5 x 29.7 cm
(21.3 x 17.5 x 11.7 in.)
- Weight
- 13.72 kg
(30.25 lb)
- Weight
- 14.6 kg
(32.2 lb) with optional Granite Volt 116 module
Pump Module
- Inlet Connection
- 3/8-in. Swagelok
- Pressure Sensor Range
- 15 to 115 kPa
- Pumping Speed
- 3 to 9 LPM
(automatically controlled at the set point, typically 8 LPM)
Accessories
(14)CABLEPCBL
2-Conductor 16 AWG Power Cable
OrderableCABLE4CBL
4-Conductor 22 AWG Cable with Drain
Orderable45309
CPEC200/300 Pump Tubing Assembly, 0.375 OD
Orderable21823
Calibration Gas Tubing Assembly
Orderable33288
8 GB microSD Flash SLC Memory Card
Retired17752
USB Memory Card Reader/Writer
OrderableEasyFlux DL
Eddy-Covariance Data Logger Program
OrderableEasyFlux WebH
EasyFlux Web Software, Campbell Scientific-Hosted
Retired38476
16 GB microSD Flash aMLC Memory Card
Orderable27158
2 GB microSD Flash SLC Memory Card
Orderable45308
CPEC200/300 Pump Tubing Assembly, 0.500 OD
OrderableEasyFlux WebS
EasyFlux Web Software, Self-Hosted
RetiredEasyFlux PC
Eddy-Covariance Post-Processing PC Software
OrderableFluoreSens 10
Sun-Induced Chlorophyll Fluorescence (SIF) System
Orderable
Related Resources
Documents
- Document
Air temperature equation derived from sonic temperature and water vapor mixing ratio for turbulent airflow sampled through closed-path eddy-covariance flux systems
January 2022
View Document - Technical Paper
An eddy-covariance system with an innovative vortex intake for measuring carbon dioxide and water fluxes of ecosystems
March 2017
View Document - Document
Field-Performance Verification of Carbon Dioxide, Water, and Nitrous Oxide Closed-Path Eddy Covariance Systems with Vortex Intakes Poster
December 2015
View Document - Manual
CPEC306/310 Closed-Path Eddy-Covariance Systems
November 2025
View Document - View all documents