CPEC300
CPEC300
End of lifeConfigurableCompact Closed-Path Eddy-Covariance System with EC155 and Pump Module
Pricing
- Model:
- CPEC300
- Item Number:
- 33595
- Warranty:
- 1 year
- Lead time:
- 14 days
Overview
The CPEC300 with EasyFlux® is a turn-key, closed-path eddy-covariance (EC) flux system for long-term monitoring of atmospheric-biosphere exchanges of carbon dioxide, water vapor, heat, and momentum. A complete system consists of a closed-path gas analyzer (EC155 closed-path gas analyzer), sonic anemometer (CSAT3A sonic anemometer), data logger (CR6 datalogger), and sample pump.
The gas analyzer’s intake design and small sample cell volume (5.9 mL) provide excellent frequency response (4.3 Hz cutoff frequency) with low total system power (12 W). Additionally, the vortex intake (United States Patent No. 9,217,692) greatly reduces maintenance and maintains frequency response compared to traditional inline filters.
Key Advantages
Ideal for applications that don't require automatic zero and span
Technical Description
The gas analyzer’s small sample cell volume (5.9 mL) minimizes the sample residence time (50 ms at the system’s nominal flow rate, 7 LPM). This gives excellent frequency response (5.8 Hz half-power bandwidth) with low total system power (12 W).
Eddy-Covariance Measurements
CO2 and H2O are measured with an EC155 Closed-Path Gas Analyzer. Three-dimensional wind speed and sonic air temperature are measured with a CSAT3A sonic anemometer head.
CPEC300 System Enclosure
The 24.9 x 34.0 cm (9.8 x13.4 in.) enclosure houses the EC100 electronics and the CR6 datalogger attached to the lid of the enclosure. The CPEC300 enclosure can be mounted to a tripod mast, CM106 tripod leg base, tower legs, or a large-diameter pole.
CPEC300 Pump Module
The pump module, a standard component of the CPEC300 system, consists of a small dual-head diaphragm pump with a brushless dc motor mounted inside a fiberglass enclosure. An integral cable connects the pump module to the CPEC300 system enclosure, which provides power, temperature measurement and control, pressure measurement, and pumping speed measurement and control.
Benefits
- Compact, entry-level system with integrated CR6 running EasyFlux<sup>®</sup> DL
- Suitable for sites with easy access to the data logger
- Simple design for easy and quick deployment
Specifications
- Operating Temperature Range
- -30° to +50°C
- Input Voltage Range
- 10.5 to 16.0 Vdc
- Power
- 12 W
(typical)
- Power
- 35 W
(maximum, at cold startup)
System Enclosure
- Dimensions
- 34 x 25 x 13 cm
(13.4 x 9.8 x 5.1 in.)
- Weight
- 4.02 kg
(8.85 lb)
Pump Module
- Inlet Connection
- 3/8-in. Swagelok
- Pressure Sensor Range
- 15 to 115 kPa
- Pumping Speed
- 3 to 9 LPM
(automatically controlled at the set point, typically 7 LPM)
- Cable Length
- 3.0 m
(10 ft)
- Dimensions
- 35.6 x 29.2 x 13.5 cm
(14.0 x 11.5 x 5.3 in.)
- Weight
- 5.4 kg
(11.8 lb)
Accessories
(14)CABLEPCBL
2-Conductor 16 AWG Power Cable
OrderableCABLE4CBL
4-Conductor 22 AWG Cable with Drain
Orderable45309
CPEC200/300 Pump Tubing Assembly, 0.375 OD
Orderable21823
Calibration Gas Tubing Assembly
OrderableCR1000KD
Keyboard/Display for CR1000(X), CR800, or CR6
Orderable33288
8 GB microSD Flash SLC Memory Card
Retired17752
USB Memory Card Reader/Writer
OrderableEasyFlux DL
Eddy-Covariance Data Logger Program
OrderableEasyFlux WebH
EasyFlux Web Software, Campbell Scientific-Hosted
Retired45308
CPEC200/300 Pump Tubing Assembly, 0.500 OD
Orderable27158
2 GB microSD Flash SLC Memory Card
Orderable38476
16 GB microSD Flash aMLC Memory Card
OrderableEasyFlux WebS
EasyFlux Web Software, Self-Hosted
RetiredEasyFlux PC
Eddy-Covariance Post-Processing PC Software
Orderable
Related Resources
Documents
- Document
Field-Performance Verification of Carbon Dioxide, Water, and Nitrous Oxide Closed-Path Eddy Covariance Systems with Vortex Intakes Poster
December 2015
View Document - Manual
EC155 Packing Information
November 2018
View Document - Document
Performance Evaluation of an Innovative Sampling System for Closed Path Eddy Covariance Measurements
View Document - Technical Paper
Damping Temperature Fluctuations in the EC155 Intake Tube
January 2017
View Document - View all documents