Overview

GRANITE Series 16- or 32-Channel 5V Analog Input Module

The Granite™ Volt 116 easily expands the channel count on your data acquisition system. It has 16 differential or 32 single-ended input channels, as well as four excitation channels. It provides programmable, precision excitation for standard sensor measurements and power outputs for controlling sensors and peripherals. The Volt 116 features a 24-bit, analog-to-digital converter with low-noise performance for superior analog measurements.

Key Advantages

Ultimate Analog Measurement Expansion Tool
Ideal for concentrated or distributed measurements

Benefits

  • 24-bit ADC and low-noise inputs for increased measurement quality
  • Distributed data acquisition
  • Channel count expansion via the CPI bus on Campbell Scientific data loggers
  • Easier to program than traditional multiplexers
  • Programmable noise rejection
  • CANbus 2.0 A/B output available with the Extended Duty (-XD) version
  • USB 2.0 interface for PC-based operation with Campbell Scientific Surveyor software

Specifications

Mounting
Standard 1-in. grid

(DIN rail mounting available)

Operating Temperature Range
-40° to +70°C

(standard)

Operating Temperature Range
-55° to +85°C

(extended)

Power Requirements
9.6 to 32 Vdc voltage
Accuracy
±(0.04% of reading + offset)

0° to 40°C

Accuracy
±(0.06% of reading + offset)

-40° to +70°C

Accuracy
±(0.08% of reading + offset)

-55° to +85°C

Number of Channels
16 differential or 32 single-ended inputs
Analog Inputs
32 single-ended or 16 differential

(with ±5000 mV, ±1000 mV, ±200 mV ranges 24 bit ADC)

Maximum Scan Rate
1 channel at 1 kHz
Maximum Scan Rate
16 channels at 167 Hz
Input Range
±5000 mV, ±1000 mV, and ±200 mV
Period Averaging
Traditional period averaging on analog input channels
CPI
For data logger connection. Baud rate selectable from 50 kbps to 1 Mbps.

(Allowable cable length varies depending on baud rate, number of nodes, cable quality, and noise environment, but can be as long as 700 m under proper conditions.)

USB
USB 2.0 full speed connection available for attaching to a PC.

(Port is used to configure the module and download updates via our Device Configuration Utility.)

Warranty
One year against defects in materials and workmanship
Dimensions
20.3 x 12.7 x 5.1 cm

(8 x 5 x 2 in.)

Weight
0.9 kg

(1.95 lb)

Typical Current Drain

Sleep
<1 mA
Active 1 Hz Scan
2 mA

(estimated)
Assumes one single-ended measurement with the first notch frequency (fN1) at 30 kHz
Note: Any sensor excitation or switched power loads will be additive to this value.

Active 20 Hz Scan
20 mA


Assumes one single-ended measurement with the first notch frequency (fN1) at 30 kHz
Note: Any sensor excitation or switched power loads will be additive to this value.

Active 1 kHz Scan
67 mA


Note: Any sensor excitation or switched power loads will be additive to this value.

Voltage/Current Excitation Outputs

Voltage Excitation
±5 V

(@ 50 mA)

Current Excitation
±2.5 mA

(±5 V compliance voltage)

Number of Voltage/Current Excitation Outputs
4

General Purpose Outputs

Number of SW5V Outputs
4
SW5V Output Resistance
30 Ω
Number of SW12V Outputs
2
Typical Limit of SW12V Outputs
200 mA
Minimum Limit of SW12V Outputs
180 mA
Number of 12V Outputs
2
Typical Limit of 12V Outputs
200 mA
Minimum Limit of 12V Outputs
180 mA

Ships With