SoilVue 10
SoilVue 10
OrderableConfigurableTDR Soil Moisture and Temperature Profile Sensor
Highest accuracy for soil moisture and temperature. TrueWave TDR technology.
Pricing
Configuration
Sign in for option pricing- 0.5m Long (w/6 Depths Readings at , 10, 20, 30, 40, 50cm) (-40 to +60C) w/o CableSoilVue10-5
- 1m Long (w/9 Depths Readings at 5, , 20, 30, 40, 50, 60, 75, 100cm) (-40 to +60C) w/o CableSoilVue10-10
Select a configuration to add to your quote
- Model:
- SoilVue 10
- Item Number:
- SoilVue10
- Warranty:
- 1 year
- Lead time:
- 30 days
Overview
The SoilVue™10 is a soil water content profile sensor powered by Campbell TrueWave™TDR technology. This soil moisture, electrical conductivity, and temperature profile sensor was developed with environmental researchers and environmental monitoring networks in mind. The SoilVue 10 represents several exciting advancements in in-situ soil measurement that make this an extremely compelling option for anyone in these applications who needs to make multiple measurements in a profile.
Campbell Scientific’s proprietary TrueWave TDR technology combines a best-in-class rise time with an advanced waveform analysis technique to determine the true travel time of a high-frequency pulse. This process achieves a high-resolution, smooth signal for defensible measurements that can be universally compared with other TDR measurements. Not all TDR-based sensors perform equally well.
Key Advantages
Easy to Install,
Excellent Soil Contact
Technical Description
The SoilVue 10 consists of TDR circuitry connected to a series of six or nine helical wave guides that make up part of the overall threaded design. The threaded design, with individual sensors built into the threads, improves sensor contact with the soil to reduce potential error from air gaps. The TDR circuitry generates a short rise time electromagnetic pulse that is applied to the helical wave guides. The elapsed two-way travel time of the applied pulse is used to calculate the dielectric permittivity of the surrounding media and determine the volumetric water content using a mixing model.
The soil water content profile sensor can be installed in a hole made by a standard 5 cm (2 in.) hand auger. Excavation machinery or expensive custom tools are not necessary to install the sensor.
The included cable has an IP67-rated M12 connector that is detachable from the sensor for easy field replacement if the cable becomes damaged.
Benefits
- Measures VWC, permittivity, EC, and temperature
- Six or nine depths measured with one sensor
- Quick and low-impact installation
- Digital output compatible with most Campbell Scientific data loggers
- Designed for long-term outdoor operation
- Proven and trusted TrueWave TDR technology
Specifications
- Measurements Made
- Volumetric water content (VWC), permittivity, electrical conductivity (EC), and temperature
- Operating Temperature Range
- -40° to +60°C
- Maximum Installation Torque
- 54 N m
(40 ft⋅lb)
- Operating Voltage Range
- 9 to 36 Vdc
- Diameter
- 5.2 cm
(2.05 in.) without threads
- Diameter
- 5.8 cm
(2.3 in.) including threads
- Maximum Cable Length
- 304.8 m
(1,000 ft)
- Length
- 0.55 m/1.05 m
(21.5 in./41.2 in.) depending on the option ordered
- Weight
- 1.9 kg/3.6 kg
(4.2 lb/7.9 lb) depending on the option ordered
Current Drain
- Active
- ~64 mA
(@ 12 Vdc)
- Quiescent
- ~1.5 mA
(@ 12 Vdc)
Measurement Depths
- 0.5 m Option
- 5, 10, 20, 30, 40, and 50 cm
(2, 4, 8, 12, 16, and 20 in.)
- 1 m Option
- 5, 10, 20, 30, 40, 50, 60, 75, and 100 cm
(2, 4, 8, 12, 16, 20, 24, 30, and 40 in.)
Electrical Conductivity
- Range
- 0 to 10 dS/m
- Accuracy
- ±2%
(0 to 2.5 dS/m)
- Accuracy
- ±5%
(full range)
Relative Dielectric Permittivity
- Range
- 1 to 80
- Accuracy
- ±1 permittivity unit
(between 4 and 42 permittivity)
Volumetric Water Content
- Range
- 0 to 100%
- Water Content Accuracy
- ±1.5% typical with most soils
Soils with high organic matter (> 12% soil organic carbon) or high clay content (> 45% clay) may need a soil-specific calibration due to the dispersive nature of these materials.
Soil Temperature
- Accuracy
- ± 0.15°C
(between -30° and +40°C)
Accessories
(7)VueCBL1
Vue Sensor Cable
OrderableVueCBL2
24 AWG Extension Cable with Five-Pin to Eight-Pin M12 Connectors
Orderable33456
SoilVue 10 Installation Kit with Auger
Orderable35118
SoilVue 10 Installation Socket and Handle
Orderable33815
SDI-12 Terminal Bus Kit
Orderable39119
DIN Rail Terminal Kit with 2 Terminals and 4 Wires
Orderable39642
Status unavailable
Related Resources
Case Studies

Réunion Island: Tropical Volcanic Watershed
Multidisciplinary research for meteorology, hydrology, hygrogeology, and hydrogeochemistry
Réunion Island
March 28, 2025
View
Utah: Flux Stations
Improving ground-truth measurement of water throughout the state
Utah, USA
June 9, 2023
View
United Kingdom: Pioneering Research in Carbon Sequestration
University-based ecology and hydrology research
United Kingdom
January 26, 2024
View
Zambia: Strengthening Climate Resilience
Harnessing climate and hydrometeorological data to build climate change resilience
Zambia (multiple locations)
December 6, 2023
View- View all case studies
Documents
Videos and Tutorials

Displaying and Customizing Units of Measurement in CampbellCloud
May 17, 2024 (3:38)
How to add units of measurement to the CampbellCloud Data Explorer display
Watch
Unboxing the Campbell Scientific Aspen 10
February 9, 2024 (1:02)
Unboxing video for the Aspen 10
Watch
Aspen 10 IoT: Bridging Network Gaps with Smart Solutions
April 8, 2024 (40:59)
Episode 1 of the Field to Cloud webinar series
Watch
Measuring Water in the Soil: A Webinar
January 21, 2021 (32:06)
Common theories for making measurements of soil water content
Watch- View all videos and tutorials