TDR200

Time-Domain Reflectometer
TDR200

TDR200

Orderable

Time-Domain Reflectometer

Time-domain reflectometer system for precise measurements of slope stability, rock deformation, and soil water content measurements.

Model:
TDR200
Item Number:
32558
Warranty:
1 year

Overview

TDR200 Time-Domain Reflectometer (-40 to +85C) (Ships as 32555, 32559, & 27555)

The TDR200 Time-Domain Reflectometer is the core of the Campbell Scientific time-domain reflectometry (TDR) system. TDR systems accurately determine soil volumetric water content, soil bulk electrical conductivity, rock mass deformation, or a user-specific time-domain measurement. One Campbell Scientific data logger can control multiple TDR200 reflectometers.

Key Advantages

Core of the TDR System

Technical Description

The TDR200 generates a short rise time electromagnetic pulse that is applied to a coaxial system that includes a TDR probe for soil water measurements. Then the reflectometer samples and digitizes the resulting reflection waveform for analysis or storage.

The elapsed travel time and pulse reflection amplitude contain information used by the on-board processor to quickly and accurately determine soil volumetric water content, soil bulk electrical conductivity, rock mass deformation, or a user-specific time-domain measurement.

The data logger collects a 250-point waveform and analyzes it in approximately two seconds. Each waveform can have up to 10,112 data points for monitoring long cable lengths used in rock mass deformation or slope stability. Advanced noise filtering and averaging make accurate measurements possible in noisy environments.

A Complete System

A complete TDR200-based system includes the TDR200, SDM8X50 multiplexers, data logger, power supply, enclosures, and probes. PC-TDR version 3 software supports TDR200 and sensor setup, troubleshooting, and program generation. This software is available, at no charge, from our website.

The SDM8X50 Multiplexer brochure, TDR Probes component category brochure, and Time-Domain Reflectometry System brochure provide additional information about the TDR system components. 

Benefits

  • Low power (half the power of the TDR100)
  • Robust
  • High sensitivity
  • High resolution
  • Low noise
  • Advanced waveform filtering
  • Advanced waveform analysis algorithm
  • Backward compatible with TDR100 systems (CRBasic data loggers only)
  • 60 Hz frequency rejection

Specifications

Measurements Made
Volumetric water content (VWC) of porous media (such as soil), soil electrical conductivity (EC), rock mass deformation
Pulse Generator Output
250 mV into 50 Ω
Output Impedance
50 Ω ±1%
Time Response of Combined Pulse Generator & Sampling Circuit
≤ 85 ps
Pulse Generator Aberrations
±16%

(within first 1 ns)

Pulse Generator Aberrations
±1%

(after 1 ns)

Pulse Length
25.5 μs
Waveform Averaging
1 to 128
Operating Temperature Range
-40° to +85°C
Power Supply
Unregulated 12 Vdc

(9.6 to 16 Vdc)
150 mA maximum, USB powered (5 Vdc)

Required Equipment
Measurement system
Dimensions
21.6 x 5.1 x 10.7 cm

(8.5 x 2.0 x 4.2 in.)

Weight
0.79 kg

(1.75 lb)

Waveform Sampling

-NOTE-
20 to 10112 waveform values over chosen length



Distance is Vp=1. Time is one-way travel.

Range
0 to 3800 m

(distance)

Range
0 to 27.75 μs

(time)

Resolution
1.35 mm

(distance)

Resolution
< 4.4 ps

(time)

Electrostatic Discharge Protection

Air
±8 kV @ 2 Ω
Contact
±4 kV @ 2 Ω
Surge
±2 kV @ 2 Ω

Current Drain

During Measurement
120 mA
Sleep Mode
1 mA

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com