26967
0871LH1 24 V Power Supply Kit
No image available
26967
Orderable0871LH1 24 V Power Supply Kit
Overview
ACC 0871LH1/24V Power Supply Kit (-25 to +70C)
The 0871LH1 24 V Power Supply Kit is used to power the heater incorporated in the 0871LH1 Freezing-Rain Sensor. The sensor's 24 V leads connect to the 0871LH1.
Technical Description
The 0871LH1 24V Power Supply Kit is used to power the heater incorporated in the 0871LH1 Freezing Rain Sensor. The sensor's 24 V leads connect to the 0871LH1.
Specifications
- Operating Temperature Range
- -25° to +70°C
(> 60°C derating: 2.5 %/K)
- Storage/Transport Temperature Range
- -40° to +85°C
- Maximum Operational Relative Humidity
- ≤ 95%
(at 25°C, non-condensing)
- Operating Voltage Display
- Green LED
- Efficiency
- > 88%
(for 230 Vac and nominal values)
- Insulation Voltage Input/Output
- 3 kV
(type test)
- Insulation Voltage Input/Output
- 3 kV
(routine test)
- Protection Class
- II
(in closed control cabinet)
- IP Rating
- IP20
- Dimensions
- 10.7 x 6.75 x 9.9 cm
(4.21 x 2.66 x 3.9 in.)
- Weight
- 0.4 kg
(14.1 oz)
Input Data
- Nominal Input Voltage
- 100 to 240 Vac
- Input Voltage Range
- 85 to 264 Vac
- Input Voltage Range
- 90 to 350 Vdc
- AC Frequency Range
- 45 to 65 Hz
- Current Consumption
- 1.3 A
(120 Vac)
- Current Consumption
- 0.8 A
(230 Vac)
- Current Consumption
- 1.3 A
(90 Vdc)
- Current Consumption
- 0.4 A
(350 Vdc)
- Nominal Power Consumption
- 194 VA
Output Data
- Nominal Output Voltage
- 24 Vdc ±1%
- Setting Range of the Output Voltage
- 22.5 to 26 Vdc
(> 24 Vdc, constant capacity restricted)
- Nominal Output Current
- 3.8 A
(-25° to +60°C)
- Derating
- 60° to 70°C
(2.5%/K)
- Output Power
- 100 W
- Typical Response Time
- < 0.4 s