HC2S3-QD

Temperature and Relative Humidity Probe for RAWS-F
No image available

HC2S3-QD

Retired

Temperature and Relative Humidity Probe for RAWS-F

Model:
HC2S3-QD
Item Number:
28669
Warranty:
1 year

Overview

HC2S3-QD Rotronic HygroClip2 Temperature/RH Probe for RAWS Station, 65 Inches Cable

The HC2S3-QD is a rugged, accurate temperature and humidity probe that is ideal for long-term, unattended applications. The probe uses an advanced capacitive sensor to measure relative humidity. The probe includes a filter to protect the sensor from dust and particles, for superior performance and reliability.

Key Advantages

Accurate and Rugged
Wired for RAWS-F Station

Technical Description

The HC2S3-QD comes with a polyethylene filter that protects its sensor from fine dust and particles and minimizes water absorption and retention. Alternatively, a Teflon filter is available for marine environments. The response time is slower when using the Teflon filter.

Specifications

Electronics Operating Limits
-40° to +100°C
Storage Temperature
-50° to +100°C
Filter
Polyethylene (standard) or Teflon (optional, ordered separately)
Current Consumption
< 4.3 mA

(@ 5 Vdc)

Current Consumption
< 2.0 mA

(@ 12 Vdc)

Supply Voltage
5 to 24 Vdc
Startup Time
1.5 s

(typical) The startup time is Rotronics specification. For programming, Campbell Scientific recommends a 2 s delay at 60°C, 3 s delay at 0°C, and 4 s delay at -40°C.

Maximum Startup Current
< 50 mA for 2 μs
Diameter
15 mm

(0.6 in.)

Cable Length
165.1 cm

(65 in.)

Length
85 mm

(3.3 in.) without connector

Length
121 mm

(4.75 in.) with connector

Weight
10 g

(0.35 oz)

Analog Outputs

Offset at 0 V
±3 mV

(maximum)

Deviation for Digital Signal
< ±1 mV

(0.1°C, 0.1% R. H.)

Air Temperature

Temperature Sensor
PT100 RTD, IEC 751 1/3 Class B
Measurement Range
-40° to +60°C

(default) Air temperature measurement ranges from -50° to +100°C are possible; contact Campbell Scientific for more information.

Output Signal Range
0 to 1 V
Accuracy at +23°C
±0.1°C

(with standard configuration settings)

Long-Term Stability
< 0.1°C/year
Sensor Time Constant
63% step change (1 m/s air flow at sensor)
Sensor Time Constant
≤ 22 s

(standard PE filter)

Sensor Time Constant
≤ 30 s

(optional Teflon filter)

Temperature Accuracy
Refer to the graph in the manual.

Relative Humidity

Sensor
ROTRONIC® Hygromer IN-1
Measurement Range
0 to 100% RH

(non-condensing)

Output Signal Range
0 to 1 Vdc
Long-Term Stability
< 1% RH per year
Response Time
Typical 10 s, 63% of a 35% to 80% RH step change

(1 m/s air flow at sensor)

Accuracy at +23°C
±0.8% RH

(with standard configuration settings)

Sensor Time Constant
63% of a 35 to 80% RH step change (1 m/s air flow at sensor)
Sensor Time Constant
≤ 22 s

(standard PE filter)

Sensor Time Constant
≤ 30 s

(optional Teflon filter)

RH Accuracy over Temperature
Refer to the graph in the manual.

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com