HC2S3-QD
HC2S3-QD
RetiredTemperature and Relative Humidity Probe for RAWS-F
Pricing
- Model:
- HC2S3-QD
- Item Number:
- 28669
- Warranty:
- 1 year
Overview
The HC2S3-QD is a rugged, accurate temperature and humidity probe that is ideal for long-term, unattended applications. The probe uses an advanced capacitive sensor to measure relative humidity. The probe includes a filter to protect the sensor from dust and particles, for superior performance and reliability.
Key Advantages
Wired for RAWS-F Station
Technical Description
The HC2S3-QD comes with a polyethylene filter that protects its sensor from fine dust and particles and minimizes water absorption and retention. Alternatively, a Teflon filter is available for marine environments. The response time is slower when using the Teflon filter.
Specifications
- Electronics Operating Limits
- -40° to +100°C
- Storage Temperature
- -50° to +100°C
- Filter
- Polyethylene (standard) or Teflon (optional, ordered separately)
- Current Consumption
- < 4.3 mA
(@ 5 Vdc)
- Current Consumption
- < 2.0 mA
(@ 12 Vdc)
- Supply Voltage
- 5 to 24 Vdc
- Startup Time
- 1.5 s
(typical) The startup time is Rotronics specification. For programming, Campbell Scientific recommends a 2 s delay at 60°C, 3 s delay at 0°C, and 4 s delay at -40°C.
- Maximum Startup Current
- < 50 mA for 2 μs
- Diameter
- 15 mm
(0.6 in.)
- Cable Length
- 165.1 cm
(65 in.)
- Length
- 85 mm
(3.3 in.) without connector
- Length
- 121 mm
(4.75 in.) with connector
- Weight
- 10 g
(0.35 oz)
Analog Outputs
- Offset at 0 V
- ±3 mV
(maximum)
- Deviation for Digital Signal
- < ±1 mV
(0.1°C, 0.1% R. H.)
Air Temperature
- Temperature Sensor
- PT100 RTD, IEC 751 1/3 Class B
- Measurement Range
- -40° to +60°C
(default) Air temperature measurement ranges from -50° to +100°C are possible; contact Campbell Scientific for more information.
- Output Signal Range
- 0 to 1 V
- Accuracy at +23°C
- ±0.1°C
(with standard configuration settings)
- Long-Term Stability
- < 0.1°C/year
- Sensor Time Constant
- 63% step change (1 m/s air flow at sensor)
- Sensor Time Constant
- ≤ 22 s
(standard PE filter)
- Sensor Time Constant
- ≤ 30 s
(optional Teflon filter)
- Temperature Accuracy
- Refer to the graph in the manual.
Relative Humidity
- Sensor
- ROTRONIC® Hygromer IN-1
- Measurement Range
- 0 to 100% RH
(non-condensing)
- Output Signal Range
- 0 to 1 Vdc
- Long-Term Stability
- < 1% RH per year
- Response Time
- Typical 10 s, 63% of a 35% to 80% RH step change
(1 m/s air flow at sensor)
- Accuracy at +23°C
- ±0.8% RH
(with standard configuration settings)
- Sensor Time Constant
- 63% of a 35 to 80% RH step change (1 m/s air flow at sensor)
- Sensor Time Constant
- ≤ 22 s
(standard PE filter)
- Sensor Time Constant
- ≤ 30 s
(optional Teflon filter)
- RH Accuracy over Temperature
- Refer to the graph in the manual.