CURS100

100-Ohm Current Terminal Input Module
CURS100

CURS100

Orderable

100-Ohm Current Terminal Input Module

Model:
CURS100
Item Number:
20598
Warranty:
1 year

Overview

CURS100 100 Ohm Current Shunt Terminal Input Module

The CURS100 enables your Campbell Scientific data logger to measure a sensor or output device that outputs a current signal (for example, 4 to 20 mA). It converts the current signal to a voltage signal.

Key Advantages

Expands Capabilities
Allows data logger to measure additional types of sensors

Technical Description

The CURS100 uses a 100 Ω resistor for the current shunt that allows currents up to 25 mA to be read on a ±2500 mV range (CR10X, CR510) and currents up to 50 mA to be read on a ±5000 mV range.

Schematic for CURS100

CURS100-to-Sensor Hookup

Benefits

  • Easy to install or remove
  • Connects directly into data logger input terminals
  • Low power consumption

Specifications

Used With
Sensors that output a current signal (4 to 20 mA)
Resistance
100 Ω

(shunt—bulk metal foil)

Tolerance
±0.01%

(@ 25°C)

Power Rating
0.25 W
Maximum Temperature Coefficient
±0.8 ppm/°C
Dimensions
1.5 x 1.5 x 2.7 cm

(0.6 x 0.6 x 1.0 in.) for body with prongs

Weight
6 g

(0.2 oz)

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com