CS215-PWS

Temperature and Relative Humidity Probe for PWS100
CS215-PWS

CS215-PWS

Retired

Temperature and Relative Humidity Probe for PWS100

Model:
CS215-PWS
Item Number:
22250
Warranty:
1 year

Overview

CS215-PWS Temperature/RH Probe for PWS100

The CS215-PWS is a temperature and relative humidity probe with a special connector on the cable for attaching to a PWS100.  It uses a Swiss-made digital humidity and temperature element that makes accurate and stable measurements. The CS215-PWS outputs an SDI-12 signal measurable by most Campbell Scientific data loggers.

Key Advantages

Competitively Priced, SDI-12 ouput
Specially cabled for PWS100

Technical Description

For this version of the CS215 Temperature and RH Probe, the cable has, instead of pigtails, a connector for attachment to the PWS100. 

The CS215 uses the Sensirion SHT75, a combined relative humidity and temperature element, to provide accurate, stable measurements. The Sensirion SHT75 element is field-replaceable, eliminating the downtime typically required for the recalibration process. The CS215 outputs an SDI-12 signal that's measurable by many Campbell Scientific data loggers.

The CS215 should be housed in a solar radiation shield—typically the 41303-5A. The 41303-5A 6-plate naturally aspirated shield attaches to a mast, crossarm, or tower leg.

Benefits

  • Accurate and stable measurements
  • Field changeable element allows on-site recalibration
  • Each sensor element is individually calibrated so no further adjustment of the probe is required
  • Low power consumption
  • Digital SDI-12 output
  • Simple data logger programming

Specifications

Sensing Element
Sensirion SHT75
Communication Standard
SDI-12 V1.3

(responds to a subset of commands)

Supply Voltage
6 to 16 Vdc

(typically powered by data logger’s 12 V supply)

Typical Current Drain
120 μA

(quiescent)

Typical Current Drain
1.7 mA

(measurement takes 0.7 s)

EMC Compliance
Tested and conforms to IEC61326:2002.
Operating Temperature Range
-40° to +70°C
Diameter
1.2 cm

(0.5 in.) at sensor tip

Diameter
1.8 cm

(0.7 in.) at cable end

Probe Length
18.0 cm

(7.1 in.) including strain relief

Cable Length
10 m

(33 ft)

Weight
350 g

(12.3 oz) with 10-m (33-ft) cable

Relative Humidity

Measurement Range
0 to 100% RH

(-20° to +60°C)

Output Resolution
0.03% RH
Accuracy
±2%

(10% to 90% range) at 25°C

Accuracy
±4%

(0% to 100% range) at 25°C

Short-Term Hysteresis
< 1% RH
Temperature Dependence
Better than ±2%

(-20° to +60°C)

Typical Stability
±1.0% per year
Response Time with Filter
< 20 s

(63% response time in still air)

Calibration Traceability
NIST and NPL standards

Temperature

Measurement Range
-40° to +70°C
Output Resolution
0.01°C
Accuracy
±0.3°C

(at 25°C)

Accuracy
±0.4°C

(5° to 40°C)

Accuracy
±0.9°C

(-40° to +70°C)

Response Time with Filter
< 120 s

(63% response time in air moving at 1 m s-1)

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com