OBS500

Smart Turbidity Meter with Antifouling Features
OBS500

OBS500

End of lifeConfigurable

Smart Turbidity Meter with Antifouling Features

Model:
OBS500
Item Number:
27784
Warranty:
1 year
Lead time:
14 days

Overview

FG OBS500 Smart Turbidity Meter w/ClearSensor(R) Technology

The OBS500 is a submersible turbidity probe with active antifouling capabilities for better measurements in biologically active water with both high and low turbidity. It outputs an SDI-12, digitally processed signal that many of our data loggers can measure. ClearSensor®  and OBS® are registered trademarks of Campbell Scientific.

Key Advantages

Accurate, Rugged
ClearSensor antifouling features, dual backscatter sensors

Technical Description

Design features of the OBS500 include the combination of a backscatter sensor (better at measuring higher turbidity) with a second sidescatter sensor (better at measuring lower turbidity). It has a shutter that is opened only during measurements, which reduces the time that algae or other organisms can cling to its optics.

To prevent biofouling and ensure better measurements, the OBS500 incorporates the ClearSensor Method (U.S. Patent No. 8,429,952). This method uses a shutter/wiper mechanism to protect and clean the optics. With the ClearSensor method, a chamber is also filled with a biocide that continuously leaches out over the optics while the probe shutter is in the closed position.

Campbell Scientific offers a disposable, plastic sleeve that can make cleanup a snap, as well as a copper sleeve that can provide additional protection, especially in sea water.

(OBS® is a registered trademark of Campbell Scientific.)

Benefits

  • Dual backscatter and sidescatter sensors used to measure turbidity
  • Patented ClearSensor antifouling method for better measurements in biologically active water
  • Shutter/wiper mechanism keeps lenses clean
  • Refillable biocide chamber prevents fouling
  • Disposable plastic sleeve facilitates cleanup
  • Optional copper sleeve for additional protection (especially for sea water) or disposable plastic sleeve facilitates easy cleanup

Specifications

Dual Probe
90° sidescatter and backscatter
Range
0 to 4000 NTU
Active and Passive Antifouling
Shutter, wiper, biocide, copper, optional removable sleeve
Concentration Accuracy
±2% of reading or 0.5 NTU

(whichever is greater)

Operating Temperature Range
0° to 40°C
Temperature Accuracy
±0.3°C
Emitter Wavelength
850 nm
Power Requirements
9.6 to 18 Vdc
Measurement Time
< 10 s
Maximum Submersion Depth
100 m

(330 ft)

Diameter
4.8 cm

(1.88 in.)

Maximum Cable Length
> 500 m

(1640 ft)

Length
27 cm

(10.63 in.)

Weight
0.59 kg

(1.3 lb)

Power Consumption

Quiescent
< 200 µA
Measurement
< 40 mA
Communication
< 40 mA
Maximum Peak Current
200 mA for 50 ms when shutter motor starts
Active Shutter Motor
< 120 mA

Outputs

SDI-12
Version 1.3, 1200 bps
RS-232
9600 bps
Analog
0 to 5 Vdc

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com