HMP60-ETS
HMP60-ETS
RetiredTemperature/RH Probe for ET Station with Shield Adapter
Pricing
- Model:
- HMP60-ETS
- Item Number:
- 30406
- Warranty:
- 1 year
- Lead time:
- 7 days
Overview
The HMP60-ETS is the replacement part for newer ET107 stations. The sensor cable terminates in a connector and is the ideal length for attachment to the ET107 ETo Weather Station. The HMP60-ETS includes an adapter that allows the sensor to fit in a MetSpec radiation shield.
The HMP60-ETS measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process.
Technical Description
The HMP60 uses the INTERCAP® capacitive RH chip. This chip is field-replaceable, which eliminates the downtime typically required for the recalibration process.
The radiation shield is a MetSpec shield modified to mount to an ET station. This six-plate naturally-aspirated radiation shield has a louvered construction that allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature. It is a double-plated shield that can help reduce the likelihood of nesting insects.
Specifications
- Supply Voltage
- 5 to 28 Vdc
(typically powered by datalogger’s 12 V supply)
- Typical Current Consumption
- 1 mA
- Maximum Current Consumption
- 5 mA
- Filter Description
- 0.2 µm Teflon membrane
- Settling Time
- 1 s
- Sensor Body Material
- AISI 316 stainless steel
- Filter Cap Material
- Chrome-coated ABS plastic
- Classification
- IP65
- Filter Diameter
- 1.2 cm
(0.5 in.)
- Sensor Diameter
- 1.2 cm
(0.5 in.)
- Sensor Length
- 7.1 cm
(2.8 in.)
- Cable Length
- 137.16 cm
(54 in.)
- Weight
- 117.93 g
(0.26 lb)
Temperature
- Temperature Sensor
- 1000 ohm Platinum Resistance Thermometer
- Measurement Range
- -40° to +60°C
- Accuracy
- ±0.6°C
Relative Humidity
- Sensor
- Vaisala’s INTERCAP capacitive chip
- Measurement Range
- 0 to 100% RH
(non-condensing)
- Accuracy (0 to 90% RH)
- ±5%
(-40° to 0°C)
- Accuracy (0 to 90% RH)
- ±3%
(0° to 40°C)
- Accuracy (0 to 90% RH)
- ±5%
(40° to 60°C)
- Accuracy (90 to 100% RH)
- ±7%
(-40° to 0°C)
- Accuracy (90 to 100% RH)
- ±5%
(0° to 40°C)
- Accuracy (90 to 100% RH)
- ±7%
(40° to 60°C)