HMP60-ETR

Temperature/RH Probe for ET Station with Shield Adapter
HMP60-ETR

HMP60-ETR

End of life

Temperature/RH Probe for ET Station with Shield Adapter

Model:
HMP60-ETR
Item Number:
30407
Warranty:
1 year

Overview

HMP60-ETR Vaisala Temperature/RH probe for ET Station w/RM Young shield adapter, 54 inch cable

The HMP60-ETR is the replacement temperature and RH sensor for older ET stations. The sensor's cable terminates in a connector and is the ideal length for attachment to the ET107 or ET106 ETo Weather Station. The HMP60-ETR includes an adapter that allows the sensor to fit in a R. M. Young radiation shield.

The HMP60-ETR measures both temperature and relative humidity and is suitable for long-term, unattended monitoring. The humidity component features a field-replaceable chip, which eliminates downtime typically required for the recalibration process.

Key Advantages

Accurate, Rugged
Ideal for long-term, unattended applications

Technical Description

The HMP60 uses the INTERCAP® capacitive RH chip. This chip is field-replaceable, which eliminates the downtime typically required for the recalibration process.

The radiation shield is a 41303-5A shield modified to mount to an ET station. This six-plate naturally-aspirated radiation shield has a louvered construction that allows air to pass freely through the shield thereby keeping the probe at or near ambient temperature.

Specifications

Supply Voltage
5 to 28 Vdc

(typically powered by datalogger’s 12 V supply)

Typical Current Consumption
1 mA
Maximum Current Consumption
5 mA
Filter Description
0.2 µm Teflon membrane
Settling Time
1 s
Sensor Body Material
AISI 316 stainless steel
Filter Cap Material
Chrome-coated ABS plastic
Classification
IP65
Filter Diameter
1.2 cm

(0.5 in.)

Sensor Diameter
1.2 cm

(0.5 in.)

Sensor Length
7.1 cm

(2.8 in.)

Cable Length
137.16 cm

(54 in.)

Temperature

Temperature Sensor
1000 ohm Platinum Resistance Thermometer
Measurement Range
-40° to +60°C
Accuracy
±0.6°C

Relative Humidity

Sensor
Vaisala’s INTERCAP capacitive chip
Measurement Range
0 to 100% RH

(non-condensing)

Accuracy (0 to 90% RH)
±5%

(-40° to 0°C)

Accuracy (0 to 90% RH)
±3%

(0° to 40°C)

Accuracy (0 to 90% RH)
±5%

(40° to 60°C)

Accuracy (90 to 100% RH)
±7%

(-40° to 0°C)

Accuracy (90 to 100% RH)
±5%

(0° to 40°C)

Accuracy (90 to 100% RH)
±7%

(40° to 60°C)

Related Resources

Connect With Us

envelope icon
Phone Numbers
General: (435) 227-9000
location icon
Corporate Address
815 W 1800 N
Logan, UT 84321
send icon
Email Address
sales@campbellsci.com

As a trusted leader in measurement systems for more than 50 years, our top priority at Campbell Scientific has always been to provide the most accurate, reliable data for research and industry.