Software applications, data logger operating systems, firmware, and drivers for Campbell Scientific products
HydroSci
v1.2.1HydroSci is used to configure and extract data from the CRS45X Recording Submersible Pressure Transducer and the OBS-3A Turbidity and Temperature Monitoring System.
Watch the Video Tutorial: Using HydroSci software with water-level recording sensors.
Revision History
v1.2.1October 9, 2017
- Fixed the OBS3A calibration date that was not displayed correctly.
- Fixed unit conversions that were not correct in the compensation calculations section. (introduced in version 1.2)
v1.2January 30, 2017
- Removed the themes from HydroSci. There is now a standard or default theme to be consistent for all.
- Updated the entire application to be able to be translated into other languages.
- Fixed minor bugs within the application.
- Upgraded View to View Pro.
v1.1December 11, 2015
- In support of varying cable lengths attached to CRS451V/CRS456V sensors, multiple baud rate settings for serial connections are now allowed.
- Added features to support the CRS451V and CRS456V.
- HydroSci will now display all files within the OBS-3A regardless of the Bad EOF Mark. This will allow the user to possibly retrieve the data if it exists within the OBS-3A even though the OBS-3A has regarded the file as having an error.
- To enable multiple CRS451V/CRS456V devices in the same communications network, the Pakbus Address of those devices may now be configured to valid values other than one (1). This opens the way for scheduled/automatic data collection using LoggerNet v4.3 or later.
- HydroSci now allows the user to manually enter a comport name in the combo box for connecting to a device. This was introduced to accommodate the rare cases in which HydroSci cannot resolve or detect a comport. This can possibly occur when registry settings are out of sync with virtual comports.
- Added more functionality to let HydroSci honor regional settings where applicable.
- Fixed and enhanced minor cosmetic and GUI control issues.
- Fixed an issue when parsing file data from an OBS-3A when a user has certain regional settings configured on their Windows operating system.
- The CRS451 connection process will now try out each possible baud rate until it finds the rate that properly connects to the device.
- Fixed an issue when displaying and setting up the OBS-3A data regarding salinity that would cause HydroSci to incorrectly parse data for the data-grid putting values in incorrect columns.
- During the connection process, HydroSci now detects the PakBus address of the CRS451. It no longer assumes the address to be 1 (one).
- Added enhancements for communication stability and optimizations.